“…It is obvious that the weight loss of 1018 carbon steel decreases and is much lower than that obtained in the blank solution. The linearity obtained indicates the absence of insoluble surface film during corrosion and that the inhibitors were first adsorbed onto the surface and thereafter impede the corrosion process [18]. The calculated values of inhibition efficiency (IE) and surface coverage  from the weight loss measurements are listed in Table 1.…”
Section: Compound IIImentioning
confidence: 99%
“…It is obvious that the weight loss of 1018 carbon steel decreases and is much lower than that obtained in the blank solution. The linearity obtained indicates the absence of insoluble surface film during corrosion and that the inhibitors were first adsorbed onto the surface and thereafter impede the corrosion process [18]. The calculated values of inhibition efficiency (IE) and surface coverage  from the weight loss measurements are listed in Table 1.…”
Section: Compound IIImentioning
confidence: 99%
“…As can be seen from the plots of this figure that in the presence of the extract the weight loss varies linearly with time, and it is lower than obtained in the free solution. These linear plots indicate the absence of insoluble surface film during corrosion, and the inhibitor was first adsorbed onto the metal surface and thereafter, inhibits the corrosion process (20) . Also it is obvious that the C.R decreases with increasing the concentration of the inhibitor.…”
Section: Resultsmentioning
confidence: 95%
“…The interaction between the inhibitor molecules and the metal surface can be provided by the adsorption isotherm. The Kinetic thermodynamic model (20) (El-Awady isotherm) has been found to give the best fit to the weight loss results of the inhibitor under test, by the following relation :…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…It is obvious that the weight loss of Al in presence of the inhibitor varies linearly with time, and is much lower than that obtained in the blank solution. The linearity obtained indicates the absence of insoluble surface film during corrosion and that the inhibitors were first adsorbed onto the surface and thereafter impede the corrosion process [10]. The calculated values of inhibition efficiency (IE) from weight loss measurements are listed in Table 1.…”
Section: Experimental Methodsmentioning
confidence: 99%