1985
DOI: 10.1016/0022-2852(85)90002-5
|View full text |Cite
|
Sign up to set email alerts
|

Infrared spectrum of isotopic carbon dioxide in the region of bending fundamental ν2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
16
2

Year Published

1997
1997
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 27 publications
(19 citation statements)
references
References 14 publications
1
16
2
Order By: Relevance
“…There is very good overall agreement between the various studies. The parameter uncertainties demonstrate Table 4 Comparison of low-lying 16 that the precision of the laser band measurements have been effectively transferred to B 00001 , D 00001 , and H 00001 through the primary energy level loops in the present analysis and that these values are similar to those reported in R92, Guelachvili [33], Bailly and Rossetti [26], and Jolma [27]. Octic distortion constants (L m ) were required to fit the 10001, 10002, and 00011 states, but L 00001 could not be significantly determined and was omitted.…”
Section: Low-lying R and P Statessupporting
confidence: 75%
See 4 more Smart Citations
“…There is very good overall agreement between the various studies. The parameter uncertainties demonstrate Table 4 Comparison of low-lying 16 that the precision of the laser band measurements have been effectively transferred to B 00001 , D 00001 , and H 00001 through the primary energy level loops in the present analysis and that these values are similar to those reported in R92, Guelachvili [33], Bailly and Rossetti [26], and Jolma [27]. Octic distortion constants (L m ) were required to fit the 10001, 10002, and 00011 states, but L 00001 could not be significantly determined and was omitted.…”
Section: Low-lying R and P Statessupporting
confidence: 75%
“…The reasons for the P state discrepancies are unclear, especially given the good agreement between our values and those Jolma [27] determined from the 16 lm spectrum. Table 3 Comparison of low-lying 16 Table 3 compares the rotational and distortion constants determined in this work for several low-lying R states with those from previous studies [14,23,26,27,33,34]. The parameters and 1r uncertainties presented in this table and subsequent comparison tables occasionally include more digits than are physically justified by the uncertainties; the extra digits are reported for numerical precision of the fitting results.…”
Section: Low-lying R and P Statescontrasting
confidence: 48%
See 3 more Smart Citations