2011
DOI: 10.1039/c0em00312c
|View full text |Cite
|
Sign up to set email alerts
|

Infrared differential absorption Lidar (DIAL) measurements of hydrocarbon emissions

Abstract: We report the application of an infrared (IR) differential absorption Lidar (DIAL) system (also capable of ultra violet measurements) built at the National Physical Laboratory (NPL), UK, to field measurements of total site emissions (controlled and fugitive) from petrochemical and landfill installations. The validation of the IR-DIAL was carried out via a series of controlled field experiments including comparison to GC analysis and tests against controlled methane releases from a test stack, all detailing agr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
40
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 59 publications
(43 citation statements)
references
References 16 publications
0
40
0
Order By: Relevance
“…The individual DIAL emission rate values were determined by combining the 2D methane distributions with the wind profile information using NPL's in-house processing suite which implements the processing steps described in Reference [8]. This processing is carried using a set of scripts within the MATLAB™ package.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…The individual DIAL emission rate values were determined by combining the 2D methane distributions with the wind profile information using NPL's in-house processing suite which implements the processing steps described in Reference [8]. This processing is carried using a set of scripts within the MATLAB™ package.…”
Section: Resultsmentioning
confidence: 99%
“…Data capture is started by a data acquisition trigger synchronized to the firing of the infrared source, with up to 16,000 samples acquired (per laser shot) with each sample spaced by a Lidar range of 3.75 m. The digitized data is averaged, typically for 500 laser shots (250 pulse pairs), to reduce random noise. More details of the NPL DIAL capability are given by Robinson et al [8]. It should be noted that the system deployed in these field campaigns is a newer version of the facility described in this paper; however, the relevant details of its operation and application are unchanged.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The scanner system directs the output beam and detection optics, giving hemispheric coverage in both the horizontal and vertical planes. For more information about the system, see Robinson et al [14].…”
mentioning
confidence: 99%