Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments 2019 2019
DOI: 10.1117/12.2536413
|View full text |Cite
|
Sign up to set email alerts
|

Information model of individual rehabilitation program efficacy in disabled persons with cardiovascular diseases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 9 publications
0
1
0
Order By: Relevance
“…Analyzing the statograms of patients with different pathological conditions of LS, we noted that the spots of the projection of the common center of mass (CCM) are significantly different in shape and location on the plane of support [12]. The standard protocol parameters of a statographic survey do not provide a complete picture of the human standing characteristics, but we have justified the possibility of using a primary time series for calculating the parameters of statograms, which can provide a great deal of information about the geometric parameters of the projection of the CCM onto the support plane [1,2,7]. Using only three statistical parameters of the series-the mathematical expectation (MO), and the minimum and maximum coordinate values-we developed an algorithm for analyzing a statogram that contains calculations of its spatial (geometric) parameters.…”
Section: Analysis Of Recent Research and Publicationsmentioning
confidence: 99%
“…Analyzing the statograms of patients with different pathological conditions of LS, we noted that the spots of the projection of the common center of mass (CCM) are significantly different in shape and location on the plane of support [12]. The standard protocol parameters of a statographic survey do not provide a complete picture of the human standing characteristics, but we have justified the possibility of using a primary time series for calculating the parameters of statograms, which can provide a great deal of information about the geometric parameters of the projection of the CCM onto the support plane [1,2,7]. Using only three statistical parameters of the series-the mathematical expectation (MO), and the minimum and maximum coordinate values-we developed an algorithm for analyzing a statogram that contains calculations of its spatial (geometric) parameters.…”
Section: Analysis Of Recent Research and Publicationsmentioning
confidence: 99%