2022
DOI: 10.1016/j.surfin.2021.101613
|View full text |Cite
|
Sign up to set email alerts
|

Influence of wavelength and pulse duration on the selective laser ablation of WOx, VOx and MoOx thin films.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 33 publications
0
5
0
Order By: Relevance
“…Interestingly, low-level ablation off the Mo surface persists even if the fluence was reduced to 1 4 the ablation threshold (0.11 J/cm 2 ) of Mo [29]. For the photoformed MoO x , the average threshold is around 0.6 J/cm 2 for 8 ps pulses of 1064 nm [59], which is expected to decrease as the pulse duration decreases. This is because longer pulses have lower peak powers [60] and are associated with higher thermal diffusion, and deeper thermal propagation into the sample, therefore requiring relatively more energy than shorter pulses for ablation [59][60][61].…”
Section: Resultsmentioning
confidence: 97%
See 1 more Smart Citation
“…Interestingly, low-level ablation off the Mo surface persists even if the fluence was reduced to 1 4 the ablation threshold (0.11 J/cm 2 ) of Mo [29]. For the photoformed MoO x , the average threshold is around 0.6 J/cm 2 for 8 ps pulses of 1064 nm [59], which is expected to decrease as the pulse duration decreases. This is because longer pulses have lower peak powers [60] and are associated with higher thermal diffusion, and deeper thermal propagation into the sample, therefore requiring relatively more energy than shorter pulses for ablation [59][60][61].…”
Section: Resultsmentioning
confidence: 97%
“…For the photoformed MoO x , the average threshold is around 0.6 J/cm 2 for 8 ps pulses of 1064 nm [59], which is expected to decrease as the pulse duration decreases. This is because longer pulses have lower peak powers [60] and are associated with higher thermal diffusion, and deeper thermal propagation into the sample, therefore requiring relatively more energy than shorter pulses for ablation [59][60][61]. Nonetheless, the ablation threshold is expected to change with each scan due to the laser-induced compositional, morphological, structural, and optical changes associated with each scan [47].…”
Section: Resultsmentioning
confidence: 97%
“…The contour plot analysis played a crucial role in visually representing response cross sections (either MSE or RA) between two variables, E and tp. Specifically, a contour plot illustrated the relationship between the E (x-axis) and the fp (y-axis) in terms of two performance metrics: RA and MSE [33], as shown in Figure 5, where Figure 5a-c 11) and (12) indicated that E, fp, and E-fp interactions were statistically significant. We favor regions with high RA values in Figure 5a.…”
Section: Contour Plot Model For Exploring the Relationship Between Tp...mentioning
confidence: 99%
“…To ensure the high-quality scribe lines demanded by these applications, researchers have extensively studied the suitability of short pulse lasers, such as picosecond and nanosecond lasers, in laser scribing processes [11,12]. These lasers offer high precision and control, enabling researchers to explore the relationship between pulse energy, pulse duration, and scribing outcomes [13,14].…”
Section: Introductionmentioning
confidence: 99%
“…Pulsed laser ablation methods exploit well-controlled light-matter interactions for surface patterning 24 , with various demonstrated uses in manufacturing 25 . The accuracy and precision of lateral patterning and thickness reduction depend not only on the properties of the materials but on key laser parameters, especially pulse duration and wavelength 26 . Ultrashort pulsed lasers (less than 10 ps) are advantageous because the ablation process occurs on timescales sufficiently short to limit thermal diffusion and the associated spread of the heat-affected zone 27 29 .…”
Section: Introductionmentioning
confidence: 99%