Influence of Tube Arrangement on the Thermal Hydraulic Performance of a Membrane Helical-Coil Heat Exchanger

Abstract: Thermalhydraulic performances of membrane helical-coil heat exchangers in in-line and staggered arrangements, are numerically investigated. The influences of Reynolds number, dimensionless pitch, and arrangement on heat transfer and flow are discussed. Moreover, the axial and tangential velocity distributions were presented for various pitches and arrangements. The results show that the membrane helical-coil arrangement has a profound effect on the thermalhydraulic performance. For the smaller radial pitch (s … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 38 publications
(53 reference statements)
0
4
0
Order By: Relevance
“…Different parameters including the flow velocity, pressure, and various pitch lengths were tested. Zhao and Che 20 numerically measured the effects of the Reynolds number, dimensionless pitch, and different configurations of the tube on the hydraulic and thermal aspects of a helical coil HX with membranes. It was shown that the in‐line tube arrangement presents a better thermal performance compared to the staggered pattern, although it exhibits higher pressure drops.…”
Section: Introductionmentioning
confidence: 99%
“…Different parameters including the flow velocity, pressure, and various pitch lengths were tested. Zhao and Che 20 numerically measured the effects of the Reynolds number, dimensionless pitch, and different configurations of the tube on the hydraulic and thermal aspects of a helical coil HX with membranes. It was shown that the in‐line tube arrangement presents a better thermal performance compared to the staggered pattern, although it exhibits higher pressure drops.…”
Section: Introductionmentioning
confidence: 99%
“…Correlations were obtained for Nu and f using the genetic algorithm. Zhao et al 25 studied thermal hydraulic performances of membrane helical coil heat exchangers in in-line and staggered arrangements, and are numerically investigated. The influences of Reynolds number, dimensionless pitch, and arrangement on heat transfer and flow are discussed.…”
Section: Introductionmentioning
confidence: 99%
“…It was shown that the overall performance of the heat exchanger with the membrane helical coil was better compared with the heat exchanger with serpentine tubes. In another numerical study conducted by Zhao and Che [43], the effects of different tube arrangements on hydraulic and thermal aspects of the performance of a helical membrane heat exchanger were studied. They examined how Reynolds number, pitch ratio, and The results indicated that the helical coil heat exchanger has a substantial effect on heat transfer enhancement.…”
Section: Introductionmentioning