2022
DOI: 10.1016/j.jdent.2022.104307
|View full text |Cite
|
Sign up to set email alerts
|

Influence of the surface humidity, implant angulation, and interimplant distance on the accuracy and scanning time of complete-arch implant scans

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
23
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 24 publications
(23 citation statements)
references
References 36 publications
0
23
0
Order By: Relevance
“…36 However, the effect of some of these variables differ when obtaining intraoral digital implant scans namely ambient lighting conditions, 37 scanning pattern, [38][39][40] and interdental space (adjacent tooth and implant scan body). Furthermore, additional factors should be considered when recording intraoral implant digital scans such as implant depth and angulation, [41][42][43][44][45] inter-implant distance, 27,46,47 and implant scan body design (material, geometry, and retention system). [48][49][50][51][52][53][54] The factors that can decrease intraoral scanning accuracy generate an accumulated scanning distortion.…”
mentioning
confidence: 99%
“…36 However, the effect of some of these variables differ when obtaining intraoral digital implant scans namely ambient lighting conditions, 37 scanning pattern, [38][39][40] and interdental space (adjacent tooth and implant scan body). Furthermore, additional factors should be considered when recording intraoral implant digital scans such as implant depth and angulation, [41][42][43][44][45] inter-implant distance, 27,46,47 and implant scan body design (material, geometry, and retention system). [48][49][50][51][52][53][54] The factors that can decrease intraoral scanning accuracy generate an accumulated scanning distortion.…”
mentioning
confidence: 99%
“…43 This is can be possibly attributed to the stitching process concept, because the inter-implant space is limited and, therefore, stitching is easier. 11,24 The inclination of dental implants is a crucial parameter affecting implant impression accuracy both for conventional 7 and for digital techniques. For digital impression methods however, there is still controversy about the influence of implant angulation.…”
Section: Discussionmentioning
confidence: 99%
“…After completing the conventional impression steps, the EVA parts around the ISSs in the reference models were trimmed to control the influence of the transparent plastic sheets on the scanning [29] (Fig. 3d).…”
Section: Intraoral Scanning Workflowmentioning
confidence: 99%
“…impression technique [28][29][30][31][32][33][34]. However, little is known about how intraoral conditions can influence the accuracy of DITs and CITs.…”
mentioning
confidence: 99%