2014
DOI: 10.18664/1994-7852.149.2014.81839
|View full text |Cite
|
Sign up to set email alerts
|

Influence of the Load Tranference Method on Short Tube Concrete Elements Filled With High-Strength Concrete

Abstract: INFLUENCE OF THE LOAD TRANFERENCE METHOD ON SHORT TUBE CONCRETE ELEMENTS FILLED WITH HIGH-STRENGTH CONCRETE Dr. sc. sciences L.I. Storozhenko, docent D.A. Yermolenko, graduate student O.V. Demchenko У статті наведено результати експериментальних досліджень коротких центральностиснутих конструктивних елементів із сталевих труб заповнених високоміцними бетонами залежно від передачі навантаження. Визначено несучу здатність, відносні деформації і встановлено характер руйнування залежно від способу завантаження та … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…In the first case, thin-wall steel concrete circular columns with t < 2.5 mm, ratio L/D ≥ 4, column diameter varying within 76 ≤ D ≤ 210 mm, length 500 ≤ L ≤ 2750 mm, yield strength of steel 186 ≤ σy ≤ 490 MPa, modulus of elasticity of steel 1.68·10 5 ≤ Es ≤ 2.17·10 5 MPa, prism strength of concrete 10 ≤ fc,prizm ≤ 50 MPa, modulus of elasticity of concrete 2.0·10 4 ≤ Ec ≤ 3.6·10 4 MPa were considered. In the series of n = 40 observations, a factor regression model was obtained as follows:…”
Section: Cfst Long Thin-walled Columnsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the first case, thin-wall steel concrete circular columns with t < 2.5 mm, ratio L/D ≥ 4, column diameter varying within 76 ≤ D ≤ 210 mm, length 500 ≤ L ≤ 2750 mm, yield strength of steel 186 ≤ σy ≤ 490 MPa, modulus of elasticity of steel 1.68·10 5 ≤ Es ≤ 2.17·10 5 MPa, prism strength of concrete 10 ≤ fc,prizm ≤ 50 MPa, modulus of elasticity of concrete 2.0·10 4 ≤ Ec ≤ 3.6·10 4 MPa were considered. In the series of n = 40 observations, a factor regression model was obtained as follows:…”
Section: Cfst Long Thin-walled Columnsmentioning
confidence: 99%
“…The extensive experimental data set on carrying capacity of the columns under various loading conditions assembled within the latest decades by the researchers across the world has enabled to study the behaviour of the columns using the techniques of mathematical statistics [1][2][3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…Analysis of research and publications. Today, buildings and structures that are designed and constructed using tube confined concrete are presented practically all over the world [4,5]. At the same time, the question of ambiguity in the calculation of such structures hinders the widespread introduction of this combination of steel and concrete, including taking into account the strengthening of their cores.…”
Section: Introductionmentioning
confidence: 99%
“…Considering a number of advantages that draw attention to the presented structures [5][6][7], the previously conducted experiments were aimed at clarifying the mechanism of development of the stress strain-state of tube confined concrete elements with a strengthened core for a more accurate and specific evaluation of their characteristics [7,8].…”
Section: Introductionmentioning
confidence: 99%
“…However, the known studies of CFST members [2,3] are mostly dedicated to the study of its operational features under the load and to its stress-strain state.…”
Section: Introductionmentioning