2021
DOI: 10.1016/j.compbiomed.2021.104612
|View full text |Cite
|
Sign up to set email alerts
|

Influence of the eye globe design on biomechanical analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
14
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(15 citation statements)
references
References 27 publications
0
14
0
1
Order By: Relevance
“…Regarding the optic nerve, typically, the complete meningeal layers have not been included, and in some cases, only the pia mater has been added [ 31 , 33 , 36 ]. In this respect, in a prior FE study we found that ONH strains decreased considerably when meninges were progressively integrated [ 35 ], which suggests that anatomical variability and oversimplification may result in inaccuracy [ 41 ].…”
Section: Introductionmentioning
confidence: 99%
“…Regarding the optic nerve, typically, the complete meningeal layers have not been included, and in some cases, only the pia mater has been added [ 31 , 33 , 36 ]. In this respect, in a prior FE study we found that ONH strains decreased considerably when meninges were progressively integrated [ 35 ], which suggests that anatomical variability and oversimplification may result in inaccuracy [ 41 ].…”
Section: Introductionmentioning
confidence: 99%
“…Studies have shown that eyeball design can affect the results of biomechanical analysis. Issarti et al [ 49 ] assessed the mechanical contribution of intraocular structures to corneal deformation by establishing the whole eyeball FE mode. The corneal mechanical deformation under different mechanical conditions revealed that the lens, iris, and muscle are also the main factors that should be considered.…”
Section: In Vitro Biomechanical Study Methods Of Eye Tissuementioning
confidence: 99%
“…Hence, the adoption of the fluid-structure interaction (FSI) analysis, where the structural domain is combined with the fluid domain, has become of great interest. Ariza-Gracia et al ( Ariza-Gracia et al, 2018 ), Maklad et al ( Maklad et al, 2020b ) and Issarti et al ( Issarti et al, 2021 ) demonstrated that the best numerical approach to reproduce the NCT is the FSI simulation. Ariza-Gracia et al ( Ariza-Gracia et al, 2018 ) considered a 2D model, which limits the study to an isotropic cornea, Maklad et al ( Maklad et al, 2020b ) and Issarti et al ( Issarti et al, 2021 ) used a limited fluid domain.…”
Section: Introductionmentioning
confidence: 99%
“…Ariza-Gracia et al ( Ariza-Gracia et al, 2018 ), Maklad et al ( Maklad et al, 2020b ) and Issarti et al ( Issarti et al, 2021 ) demonstrated that the best numerical approach to reproduce the NCT is the FSI simulation. Ariza-Gracia et al ( Ariza-Gracia et al, 2018 ) considered a 2D model, which limits the study to an isotropic cornea, Maklad et al ( Maklad et al, 2020b ) and Issarti et al ( Issarti et al, 2021 ) used a limited fluid domain. Even though the cornea contains multi-scale structures with distinct patterns of fiber organization ( Blackburn et al, 2019 ), to the best of authors knowledge, current FSI solutions ( Ariza-Gracia et al, 2018 ) ( Maklad et al, 2020b ) ( Issarti et al, 2021 ) do not account for the anisotropy of the cornea in the simulation.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation