2017
DOI: 10.1080/13102818.2017.1327331
|View full text |Cite
|
Sign up to set email alerts
|

Influence of structural dimensions of micro-pillar array in reaction field on sensitivity of enzyme-linked immunosorbent assay (ELISA)

Abstract: For high sensitivity and rapid reaction of enzyme-linked immunosorbent assay (ELISA), the filmstack reaction field with micro-pillars array was designed and developed. The film-stack reaction field was fabricated by a nanoimprint process and an automatic punch-press process. The films with different gaps between micro-pillars (5, 10 and 50 mm) were prepared. These reaction fields were evaluated by IgA ELISA using 96-well microtitre plates and the computational simulation analysis of the fluid flow and the part… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 7 publications
(13 citation statements)
references
References 27 publications
0
11
0
Order By: Relevance
“…Figure 1 shows images of the film-stack reaction field. Film-stack reaction fields were fabricated by a nanoimprint process and a punch-press process for the molding of micropillars arrayed on base films, and the shaping and stacking of base films, respectively, in accordance with our previous studies [ 16 , 17 ]. A polyethylene terephthalate (PET) sheet and acrylic resin were used for the base film and micropillars, respectively.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Figure 1 shows images of the film-stack reaction field. Film-stack reaction fields were fabricated by a nanoimprint process and a punch-press process for the molding of micropillars arrayed on base films, and the shaping and stacking of base films, respectively, in accordance with our previous studies [ 16 , 17 ]. A polyethylene terephthalate (PET) sheet and acrylic resin were used for the base film and micropillars, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…IgA ELISA was carried out using wells with or without film-stack reaction fields with micropillar arrays having different dimensions at room temperature. The procedure followed is the same as described in our previous study [ 17 ]. For the incubation of human IgA (Bethyl Laboratories, Inc., Montgomery, TX, USA) on the surfaces of wells and the film-stack reaction fields, 100 µL of 1% purified human IgA diluted in 0.1 mol/L carbonate buffer solution (CBS, pH = 9.5) was added to each well.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations