2019
DOI: 10.1016/j.jobe.2018.10.024
|View full text |Cite
|
Sign up to set email alerts
|

Influence of spherical and crushed waste Cathode-Ray Tube (CRT) glass on lead (Pb) leaching and mechanical properties of concrete

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 30 publications
(14 citation statements)
references
References 35 publications
1
9
0
Order By: Relevance
“…The lower rate of expansion of TS mortars was attributed to the rough texture and angularity of aggregates, which provided a denser microstructure. This has been reported by other researchers [29,30]. However, the contribution of the fine aggregate's hardness contributed to the compactness observed in TS50 mortars.…”
Section: Alkali-silica Reactivitysupporting
confidence: 82%
“…The lower rate of expansion of TS mortars was attributed to the rough texture and angularity of aggregates, which provided a denser microstructure. This has been reported by other researchers [29,30]. However, the contribution of the fine aggregate's hardness contributed to the compactness observed in TS50 mortars.…”
Section: Alkali-silica Reactivitysupporting
confidence: 82%
“…Introducing CRT glass into the geopolymer mixture has not been very popular so far, but a lot of scientists successfully encapsulated separate heavy metals within the geopolymer matrix [ 37 , 59 , 60 , 61 , 62 , 63 ]. Many scientific investigations prove also similar capabilities of concrete for the encapsulation of lead from CRT glass and substantial reductions in Pb leaching [ 16 , 18 , 19 , 34 ].…”
Section: Discussionmentioning
confidence: 97%
“…According to the different studies, the total replacement of natural aggregate with a CRT aggregate can cause a decrease in compressive strength by 10–27% [ 12 , 13 , 14 , 15 , 16 ], a decrease in flexural strength by 26–40% [ 13 , 14 ], and a fall in splitting tensile strength by 10–23% [ 12 , 15 , 16 ]. CRT glass was used as a replacement of fine aggregate in most studies [ 12 , 13 , 14 , 15 ] and as a replacement of a coarse aggregate in one case [ 16 ]. There are also papers reporting an increase in compressive and flexural strength after overall or partial (100% or 80% by weight) replacement of natural fine aggregates (sand) with CRT glass [ 17 ].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations