Influence of Secondary Radiation on Image Quality

Abstract: On the basis of observations concerning non-screen films and xerox plates a theory is proposed as to how the image quality is impaired by secondary radiation. The theory includes an explanation of why xerox plates and industrial roentgen films of a high silver content are less affected by secondary radiation than conventional roentgen films.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
8
0

Year Published

1975
1975
1981
1981

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 13 publications
(4 reference statements)
0
8
0
Order By: Relevance
“…This after-treatment consisted in contact copying the double-emulsioned original film onto a single-emulsioned finegrain film (Kodalith Ortho Type 3). In this copying most of the granularity of the original film is lost, the mottle still being preserved (SELIN & REICHMANN 1979). The elimination of the granularity makes evaluation of the mottle considerably easier.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…This after-treatment consisted in contact copying the double-emulsioned original film onto a single-emulsioned finegrain film (Kodalith Ortho Type 3). In this copying most of the granularity of the original film is lost, the mottle still being preserved (SELIN & REICHMANN 1979). The elimination of the granularity makes evaluation of the mottle considerably easier.…”
Section: Methodsmentioning
confidence: 99%
“…The exposure arrangement, including tube, grid, cassette, and devices for measurement of tube potential and (relative) incident radiation dose, appears in Fig. 2, p. 554 in SELIN & REICHMANN (1979).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The Medichrome films were inspected according to principles to be described. The second mode of inspection was per formed according to SELIN & REICHMANN (1977). The roentgen films were copied onto a fine-grained film.…”
Section: Depicting Quality When the Medichrome Film Was Introduced mentioning
confidence: 99%
“…However, accumulating evidence indicates that there is another property of the film which is not correlated to the parameters of the characteristic curve in any simple way, namely the number of grains per unit area (DAINTY & SHAW 1974, SELIN et coll. 1975, SELIN & REICHMANN 1977, REICHMANN et coll. 1978).…”
mentioning
confidence: 99%