2014
DOI: 10.1016/j.prosdent.2014.03.004
|View full text |Cite
|
Sign up to set email alerts
|

Influence of reverse torque values in abutments with or without internal hexagon indexes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
10
0
2

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 14 publications
0
10
0
2
Order By: Relevance
“…The Morse system is defined in regard to the form of adaptation by friction between the metallic surfaces, known as cold welding, characterized by requirement of a reverse torque greater than the insertion torque to release the abutment. [16] In the present investigation, the initial torque given in the NI Pilar Flex abutments was 32 N/cm, but after the cycling fatigue test, two of the samples from this group had a removal torque of 34 N/cm. This stability gain did not occur in the IN Pilar Flex, which shows that only 5.4% of all 37 samples (IN + NI group) presented the “cold welding effect.…”
Section: Discussionmentioning
confidence: 52%
See 1 more Smart Citation
“…The Morse system is defined in regard to the form of adaptation by friction between the metallic surfaces, known as cold welding, characterized by requirement of a reverse torque greater than the insertion torque to release the abutment. [16] In the present investigation, the initial torque given in the NI Pilar Flex abutments was 32 N/cm, but after the cycling fatigue test, two of the samples from this group had a removal torque of 34 N/cm. This stability gain did not occur in the IN Pilar Flex, which shows that only 5.4% of all 37 samples (IN + NI group) presented the “cold welding effect.…”
Section: Discussionmentioning
confidence: 52%
“…Implant dentistry is a constantly evolving specialty, where antirotational systems for prosthesis–implant connections have been frequently modified in pursuit of a better adaptation with fewer risks of fracture and abutment retaining screw loosening. [12]…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, dental implants with Morse taper connection or internal hex connection showed similar failure rate 10 . Since these two types of connection designs have their own advantages and disadvantages, recently, manufacturers combined these two types of connection designs and came up with internal hex combined with Morse taper design 11 , 12 . Hopefully, this new design can combine the benefits of internal hex and Morse taper designs.…”
Section: Discussionmentioning
confidence: 99%
“…The design of the implant connection may also influence the implant-abutment interface, since this is the area of higher stress concentration in the system. 15 16 17 External connections (EH) have the lowest torque loosening, when compared with the internal hexagonal connection (IH), 18 19 and better stress distribution, since they present a higher contact area between the abutment and implant platforms than IH. 20…”
Section: Introductionmentioning
confidence: 99%