2021
DOI: 10.1016/j.jmrt.2021.09.143
|View full text |Cite
|
Sign up to set email alerts
|

Influence of polyethylene glycol on the physical properties of Co0.2Fe2.8O4 nanoparticles used as MRI contrast agent; synchrotron radiation Fe K-edge XAFS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 57 publications
0
10
0
Order By: Relevance
“…6. The first derivative of the XANES spectrum gives a more resolved and distinguished peak position more than that in case of original XANES direct spectrum [13]. It is observed that the first inflection point corresponding to the pre-edge position of the LFO sample is very close to that of the Fe 2 O 3 (Fe 3? )…”
Section: Local/atomic Structural Study: Xafs Analysismentioning
confidence: 85%
See 3 more Smart Citations
“…6. The first derivative of the XANES spectrum gives a more resolved and distinguished peak position more than that in case of original XANES direct spectrum [13]. It is observed that the first inflection point corresponding to the pre-edge position of the LFO sample is very close to that of the Fe 2 O 3 (Fe 3? )…”
Section: Local/atomic Structural Study: Xafs Analysismentioning
confidence: 85%
“…The refined input fitting EXAFS parameters were the amplitude reduction factor S 0 2 , mean-square relative displacement r 2 , the interatomic bond lengths R, the absorption edge energy shift between the sample and the theoretical model DE 0 . The refinement of the relative contribution of tetrahedral and octahedral site-occupancy for the Fe ions was also included in the EXAFS fitting analysis [13].…”
Section: Experimental Procedures: Materials and Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Further, in order to confirm the oxidation state(s) of the Mn ions in the samples, the first derivative of the XANES spectra [d(E)/dE] is necessary to provide a more accurate and distinguished absorption peak position of both the sample and the standards, compared with the original XANES collected spectra(Imam et al, 2021a). Consequently, Fig.7(b)shows the first derivative [d(E)/dE] of the Mn K-edge XANES spectra of the ZnO NPs doped with Mn before and after irradiation at different x along with those of the reference Mn standards.…”
mentioning
confidence: 99%