2011
DOI: 10.3997/1873-0604.2011037
|View full text |Cite
|
Sign up to set email alerts
|

Influence of physical and chemical properties on the low‐frequency complex conductivity of peat

Abstract: Organic layers are heterogeneous in space and their composition changes over time. This poses challenges to ecohydrologists, subsurface hydrologists and ground engineers in characterizing subsurface peat structures and predicting their behaviour over time. Peat deposits can be characterized by performing electrical surveys, provided that the complex conductivity of peat is understood and connected to its physical and chemical properties. Low-frequency (0.1-1000 Hz) induced polarization measurements were carrie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 50 publications
(107 reference statements)
0
10
0
Order By: Relevance
“…However, Ponziani et al . () did not find correlations between CEC and σ′ or σ″ (non‐significant coefficients of determination of −0.1 and −0.14, respectively). They measured σ′ and σ″ of water‐saturated samples, whereas our samples included unsaturated conditions as well.…”
Section: Discussionmentioning
confidence: 85%
See 2 more Smart Citations
“…However, Ponziani et al . () did not find correlations between CEC and σ′ or σ″ (non‐significant coefficients of determination of −0.1 and −0.14, respectively). They measured σ′ and σ″ of water‐saturated samples, whereas our samples included unsaturated conditions as well.…”
Section: Discussionmentioning
confidence: 85%
“…The dominant effect of σ w on σ′ was described by Ponziani et al . () as well, who also used a multisite dataset. Thus, a multisite analysis of σ′ is not suitable for determining the properties of peat that are used to describe its condition.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…() reported a strong correlation between peat CEC and quadrature conductivity (IP parameter), while Ponziani et al . () could not find any correlation between the IP response and various sample characteristics such as decomposition state, water content, organic content and CEC.…”
Section: Microbially Mediated Processes and Applicationsmentioning
confidence: 77%
“…a,b; Grunat, Slater and Wehrer ); organic fraction properties (Ponziani et al . ), including also the presence of bacteria (Abdel Aal et al . ) or contaminants (Vanhala ; Martinho, Almeida, and Senos Matias ; Saltas et al .…”
Section: Introductionmentioning
confidence: 99%