2010
DOI: 10.1179/146701010x12671177204822
|View full text |Cite
|
Sign up to set email alerts
|

Influence of Non-Optimal Levels of Electrical Stimulation in Cochlear Implantees on Hearing Benefits

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0
1

Year Published

2016
2016
2020
2020

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 2 publications
0
1
0
1
Order By: Relevance
“…In general, a CI recipient attends about six appointments in the first year after implantation until the values set for specific CI parameters such as current levels are stable; subsequently the MAPs are reviewed annually (Shapiro and Bradham, 2012; Uhler and Gifford, 2014; Vaerenberg et al, 2014). The fitting of an individualised, usable, accurate program is a critical part of the postoperative rehabilitation management program and can significantly influence CI recipient outcomes (Baudhuin et al, 2012; Boyd et al, 2010; Boyle and Moore, 2015; Sainz et al, 2003; Wasowski et al, 2010; Zhou and Pfingst, 2014).…”
Section: Introductionmentioning
confidence: 99%
“…In general, a CI recipient attends about six appointments in the first year after implantation until the values set for specific CI parameters such as current levels are stable; subsequently the MAPs are reviewed annually (Shapiro and Bradham, 2012; Uhler and Gifford, 2014; Vaerenberg et al, 2014). The fitting of an individualised, usable, accurate program is a critical part of the postoperative rehabilitation management program and can significantly influence CI recipient outcomes (Baudhuin et al, 2012; Boyd et al, 2010; Boyle and Moore, 2015; Sainz et al, 2003; Wasowski et al, 2010; Zhou and Pfingst, 2014).…”
Section: Introductionmentioning
confidence: 99%
“…Obserwowalny wzrost rozumienia świadczy o plastyczności OUN, która pozwala na uruchomienie odpowiednich mechanizmów kompensacyjnych, w rezultacie których przetwarzanie informacji o dźwiękach mowy w OUN dostosowuje się do warunków degradacji informacji związanej ze stymulacją elektryczną [32]. Dlatego też dobór parametrów stymulacji w trakcie ustawiania systemu implantu powinien być tak prowadzony, aby wzmacniać mechanizmy kompensacyjne w OUN [33,72]. Mechanizmy te uruchamiane są również poprzez treningi percepcyjne [73].…”
Section: Odbieranie Wiadomości Ustnej (Rozumienie)unclassified