2016
DOI: 10.1016/j.epsr.2015.09.008
|View full text |Cite
|
Sign up to set email alerts
|

Influence of non-dispatchable energy sources on the dynamic performance of MicroGrids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 11 publications
0
7
0
Order By: Relevance
“…The case study presented here was based on the R&D Project "Microgrids with intermittent sources applied in isolated areas", presented by the Energy Group of the Department of Automation and Electrical Engineering of Polytechnic School-USP in the year of 2012 (Martinez et al, 2016). The main objective of this project was to supply energy to small isolated communities in the interior of the Amazon.…”
Section: Application Of the Proposed Methods To Microgridsmentioning
confidence: 99%
“…The case study presented here was based on the R&D Project "Microgrids with intermittent sources applied in isolated areas", presented by the Energy Group of the Department of Automation and Electrical Engineering of Polytechnic School-USP in the year of 2012 (Martinez et al, 2016). The main objective of this project was to supply energy to small isolated communities in the interior of the Amazon.…”
Section: Application Of the Proposed Methods To Microgridsmentioning
confidence: 99%
“…The proposed method was applied in a case study based on the R&D Project "Minigrid with intermittent sources to serve isolated areas", which was a project conceived by a research group and implemented in an isolated community in 2012 [39]. The project's main goal was to develop and implement a solar-diesel battery microgrid, which we take as the system-as-is.…”
Section: Case Study: Energy Supply In An Isolated Communitymentioning
confidence: 99%
“…This Generally, the bi-directional battery inverter provides this reference; however, this can also be provided by the genset. Today, the bi-directional battery inverter is generally associated with the use of the V/f droop functions (droop control) for compatible parallel operation with a genset [32]. Note that by combining the two previous topologies (DCand AC-coupling), it is possible to create a combined AC-DC-coupling topology, with part of the solar system connected directly to the DC bus and part to the AC side.…”
Section: Comparative Analysesmentioning
confidence: 99%
“…However, to reduce the consumption of fossil fuels and to minimize the need for maintaining gensets, the use of renewable energy sources, such as solar, wind, and biomass, combined with gensets is becoming more common [4,17,21,23,25,[29][30][31][32]. Another important factor to consider is the season throughout the year, i.e., Ayodele et al [33] demonstrated that during the dry season, the combination of Photovoltaic (PV)-wind power is the best renewable energy generation option, meanwhile, the best renewable energy generator option for the rainy season is the combination of PV-wind power-hydrokinetic turbine.…”
Section: Introductionmentioning
confidence: 99%