2020
DOI: 10.1186/s12871-020-00991-2
|View full text |Cite
|
Sign up to set email alerts
|

Influence of measurement principle on total hemoglobin value

Abstract: Background: Total hemoglobin (tHb) measurement is indispensable for determining the patient's condition (hemorrhagic vs. ischemic) and need for blood transfusion. Conductivity-and absorbance-based measurement methods are used for blood gas analysis of tHb. For conductivity-based measurement, tHb is calculated after converting blood conductivity into a hematocrit value, whereas absorbance measurement is based on light absorbance after red blood cell hemolysis. Due to changes in plasma electrolytes and hemolysis… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 7 publications
(5 reference statements)
0
6
0
Order By: Relevance
“…For example, recent diets, work and rest time, activity intensity, and the stress state of volunteers may affect the results of liver function, kidney function, blood glucose, blood lipid, electrolyte, and muscle enzyme tests (18)(19)(20)(21). In addition, hemolysis of samples may affect lactate dehydrogenase, aspartate transaminase, and kalemia test (22,23). Secondly, problems such as different testing equipment and reagents in different regions and different races will lead to different reference ranges for laboratory tests (22,23).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…For example, recent diets, work and rest time, activity intensity, and the stress state of volunteers may affect the results of liver function, kidney function, blood glucose, blood lipid, electrolyte, and muscle enzyme tests (18)(19)(20)(21). In addition, hemolysis of samples may affect lactate dehydrogenase, aspartate transaminase, and kalemia test (22,23). Secondly, problems such as different testing equipment and reagents in different regions and different races will lead to different reference ranges for laboratory tests (22,23).…”
Section: Discussionmentioning
confidence: 99%
“…In addition, hemolysis of samples may affect lactate dehydrogenase, aspartate transaminase, and kalemia test (22,23). Secondly, problems such as different testing equipment and reagents in different regions and different races will lead to different reference ranges for laboratory tests (22,23). As a result, it is difficult for researchers in different research centers to define the scope of no clinical significance (NCS).…”
Section: Discussionmentioning
confidence: 99%
“…Closer temporal alignment of data collection or replication of Cera-Check HbFe 2+ data using an average of multiple readings, may assist to reduce outliers. Discrepancies between absorbance-based measurements of haemoglobins and those using biosensors reliant on different analytical principles may also occur due to haemolysis [49], or if the concentration of reticulocytes varies between individuals [50], neither of which we sought to qualify. Unlike laser flow cytometry used in automatic haematology analysers, we obtained no information about the size and shape of cells [51], meaning that it is also possible that variation in several erythrocyte indices, such as mean crepuscular volume (MCV) could also have accounted for variations in absorbance data relative to total HbFe 2+ concentrations [52].…”
Section: Plos Onementioning
confidence: 99%
“…The blood sample passes through a fluidic channel where its conductance is measured by measuring the potential difference between the two electrodes placed across the fluidic channel. After correcting the variable conductivity of plasma through the concentration measurement of sodium and potassium in the sample, the hematocrit value is estimated according to the characteristic inverse relationship between the number and size of RBCs and their electrical conductance in the blood specimen. , Corrections need to be applied using the relative conductivity of plasma and its temperature before Hgb concentration is then calculated. The Epoc (Siemens Medical Solutions Diagnostics, Zurich, Switzerland, ), ABL77 Series Blood Gas and Electrolyte Analyzer, and iSTAT (Abbott, Princeton, NJ) devices use this technique for hematocrit level measurement.…”
Section: Current Technologies Of Hemolysis Measurementsmentioning
confidence: 99%