Influence of marginal bone resorption on two mini implant-retained mandibular overdenture: An in vitro study

Abstract: PURPOSE To investigate the biomechanical effect of marginal bone resorption (MBR) on the mandibular mini implant (MI)-retained overdenture (MI-OD) on the edentulous model. MATERIALS AND METHODS The experimental mandibular edentulous model was modified from a commercial model with 2 mm thick artificial soft tissue under denture base. Two MIs (Φ2.6 mm × 10 mm) were bilaterally placed between the lateral incisor and the canine area and attached with magnetic attachments. T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 39 publications
(12 reference statements)
0
9
0
1
Order By: Relevance
“…Insertion of two MDIs showed good survival rates and low amounts of marginal bone loss only when used for retention of removable partial dentures [16][17][18]. However, the clinical outcomes of only two MDIs retaining a complete mandibular OD are still doubtful [19][20][21][22]. To the best of our knowledge, no longitudinal clinical reports are available when only one MDI, inserted in the midline of the mandible, was used for the retention of a complete OD.…”
Section: Introductionmentioning
confidence: 99%
“…Insertion of two MDIs showed good survival rates and low amounts of marginal bone loss only when used for retention of removable partial dentures [16][17][18]. However, the clinical outcomes of only two MDIs retaining a complete mandibular OD are still doubtful [19][20][21][22]. To the best of our knowledge, no longitudinal clinical reports are available when only one MDI, inserted in the midline of the mandible, was used for the retention of a complete OD.…”
Section: Introductionmentioning
confidence: 99%
“…The usage of mini implant to support an overdenture has become increasingly accepted and advocated owing to their reduced diameter enabling practitioners to insert them in narrow alveolar ridges with less complex surgical techniques lowering postoperative morbidity, speeding up healing process and increasing patient's acceptance 10 . Recent guidelines support the insertion of four mini implants to support a mandibular overdenture 30 . Most research work is directed at standard diameter implants, there is relative knowledge insufficiency about clinical performance of mini implants, surrounding bone, esthetic expectations, patient's biting force and appropriate occlusal scheme.…”
Section: Discussionmentioning
confidence: 99%
“…The accuracy of the desktop scanner used in the present study was calibrated before the experiment, and the scanning accuracy of less than 10 µm was verified by the manufacturer. The present study evaluated the contact accuracy of the implant prosthesis manufactured by each group, but the previous study evaluated the strain around implant [ 33 ]. The implant prosthesis should be passively connected to the implant for a good long-term prognosis, so that less strain around implants should be given [ 33 ].…”
Section: Discussionmentioning
confidence: 99%
“…The present study evaluated the contact accuracy of the implant prosthesis manufactured by each group, but the previous study evaluated the strain around implant [ 33 ]. The implant prosthesis should be passively connected to the implant for a good long-term prognosis, so that less strain around implants should be given [ 33 ]. The reason for evaluating the contact accuracy of the implant prosthesis in the present study is that the contact accuracy can affect the strain around implant.…”
Section: Discussionmentioning
confidence: 99%