2023
DOI: 10.1111/clr.14042
|View full text |Cite
|
Sign up to set email alerts
|

Influence of drilling sequence and guide‐hole design on the accuracy of static computer‐assisted implant surgery in extraction sockets and healed sites—An in vitro investigation

Abstract: Objectives: To evaluate the effect of drilling sequence, guide-hole design, and alveolar ridge morphology on the accuracy of implant placement via static computer-assisted implant surgery (sCAIS). Materials and Methods: Standardized maxillary bone models including single-tooth gaps with fresh extraction sockets or healed alveolar ridge morphologies were evaluated in this study. Implants were placed using different drilling sequences (i.e., complete [CDS] or minimum [MDS]), and guide-hole designs (i.e., manufac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
0
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 38 publications
0
0
0
Order By: Relevance
“…Therefore, clinicians should take this information into consideration since both factors possess the potential to accumulate. Nevertheless, the clinical deviations might be influenced by a variety of factors, including the CAIS system, alveolar ridge morphology, location, drilling protocol, guide and guidehole design, and guide support (Chen et al, 2022;Couso-Queiruga et al, 2023;Dulla et al, 2023;El Kholy, Ebenezer, et al, 2019;Li et al, 2022;Raabe, Dulla, et al, 2023;Raabe, Schuetz, et al, 2023;Sittikornpaiboon et al, 2021).…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, clinicians should take this information into consideration since both factors possess the potential to accumulate. Nevertheless, the clinical deviations might be influenced by a variety of factors, including the CAIS system, alveolar ridge morphology, location, drilling protocol, guide and guidehole design, and guide support (Chen et al, 2022;Couso-Queiruga et al, 2023;Dulla et al, 2023;El Kholy, Ebenezer, et al, 2019;Li et al, 2022;Raabe, Dulla, et al, 2023;Raabe, Schuetz, et al, 2023;Sittikornpaiboon et al, 2021).…”
Section: Discussionmentioning
confidence: 99%
“…Higher accuracies were also shown in the sCAIP group versus implants that were placed via a free-handed protocol (Chen et al, 2022;Li et al, 2022;Raabe, Schuetz, et al, 2023). However, there are a plethora of factors that may influence the accuracy of the final implant position such as the macroscopic design of the implant fixture (Schnutenhaus et al, 2021), surgical guide-design (Dulla et al, 2023;Henprasert et al, 2020;Raabe, Schuetz, et al, 2023), ridge morphology (Dulla et al, 2023;Raabe, Dulla, et al, 2023), and the surgical guide support (El Kholy et al, 2019).…”
Section: Introductionmentioning
confidence: 99%