Abstract: Dry-assembled precast concrete frame structures are typically made with dowel beam-to-column connections, which allow relative rotation along the beam direction. In the orthogonal direction the rotation of the beam is prevented but again the connections of the superimposed floor elements allow for relative rotation. All the ductility and energy dissipation demand in case of seismic action is therefore concentrated at the base of cantilever columns. Hence, the column-to-foundation connection plays a key role on… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
19
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 52 publications
(20 citation statements)
references
References 6 publications
0
19
0
Order By: Relevance
“…The various hysteretic shapes are reported in Figure 4 (1 example case for every structural type). Details on the geometrical/mechanical properties of the specimens are not presented in this paper for the sake of brevity, while exhaustive information can be found in the above‐cited referenced papers . The corresponding EVD curves shown in Figure 5 (1 example case for every structural type) are evaluated based on the EVD vectors associated to approaches (i) and (ii).…”
Section: Evaluation Of the Equivalent Viscous Damping Curves From Cycmentioning
confidence: 99%
See 1 more Smart Citation
“…The various hysteretic shapes are reported in Figure 4 (1 example case for every structural type). Details on the geometrical/mechanical properties of the specimens are not presented in this paper for the sake of brevity, while exhaustive information can be found in the above‐cited referenced papers . The corresponding EVD curves shown in Figure 5 (1 example case for every structural type) are evaluated based on the EVD vectors associated to approaches (i) and (ii).…”
Section: Evaluation Of the Equivalent Viscous Damping Curves From Cycmentioning
confidence: 99%
“…Details on the geometrical/mechanical properties of the specimens are not presented in this paper for the sake of brevity, while exhaustive information can be found in the above-cited referenced papers. [36][37][38][39][40][41][42][43][44][45][46][47][48][49][50] The corresponding EVD curves shown in Figure 5 (1 example case for every structural type) are evaluated based on the EVD vectors associated to approaches (i) and (ii). Each point of the EVD vectors is evaluated by considering the mean value of the EVD factors of the 3 cycles associated to a determined imposed displacement.…”
Section: Evaluation Of the Equivalent Viscous Damping Curves From Cmentioning
confidence: 99%
“…The structural layout of the precast concrete structures considered herein, typical of industrial and commercial buildings, is composed of cantilever columns pin‐connected to prestressed RC beams spanning in one direction, which support prestressed concrete roof elements spanning in the transverse direction. The columns are embedded in a grouted socket left in the footing or connected to the foundation by means of mechanical devices or grouted sleeves . Industrial and commercial precast concrete buildings are typically characterized by higher interstorey height and higher roof flexibility compared to RC buildings.…”
Section: Introductionmentioning
confidence: 99%
“…Cyclic and pseudo‐dynamic tests on full‐scale prototypes of dry‐assembled structures with steel angle floor‐to‐beam connections were carried out in the framework of the Precast Structures EC8 (Growth) EU‐funded research project . Within the Safecast EU‐funded research project, pseudo‐dynamic tests were performed on a multistorey full‐scale prototype where direct dowel connections were used to connect the floor elements to the supporting beam . The cited experimental campaigns were focused on the overall seismic behavior of the structure.…”
Section: Introductionmentioning
confidence: 99%