Influence of Different Anesthetics on Skin Oxygenation Studied by Electron Paramagnetic Resonance in vivo

Abstract: The effects of two general anesthetics on skin oxygenation in mice are evaluated by electron paramagnetic resonance oximetry. Up to now no data on the effects of different anesthetics on skin oxygenation could be found. In this study animals were anesthetized with ketamine/xylazine or isoflurane, and partial pressure of oxygen (pO2) in the skin, heart rate and hemoglobin oxygen saturation were followed as a function of time and inhaled oxygen concentration. The skin pO2 significantly incr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
12
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(13 citation statements)
references
References 55 publications
(59 reference statements)
1
12
0
Order By: Relevance
“…These parameters were not assessed in our study. Whereas Henke et al [1] reported normoxic arterial oxygen saturation for KX anesthesia, our results exhibiting hypoxia are supported by the findings of Abramovic et al [12]. Although KX combinations and ketamine alone have been used for anesthesia over decades [2,14], multiple shortcomings have been reported.…”
Section: Discussionsupporting
confidence: 87%
See 2 more Smart Citations
“…These parameters were not assessed in our study. Whereas Henke et al [1] reported normoxic arterial oxygen saturation for KX anesthesia, our results exhibiting hypoxia are supported by the findings of Abramovic et al [12]. Although KX combinations and ketamine alone have been used for anesthesia over decades [2,14], multiple shortcomings have been reported.…”
Section: Discussionsupporting
confidence: 87%
“…In previous studies, it has been reported that KX anesthesia causes an increase in heart rate and lowers arterial blood pressure and breath rate in rodents [1,2,6,9,[12][13][14][15][16]. These parameters were not assessed in our study.…”
Section: Discussionmentioning
confidence: 89%
See 1 more Smart Citation
“…Healthy skin has a high pO2 level (8-13 kPa) but in tumors or hypoxic wounds the pO2 level can fall to 0.7 kPa [6;15]. Another process that can influence the skin pO2 is anesthesia, different type of anesthetics influence the skin perfusion in different ways [1]. The LED controllers are tuned that all the wavelengths give the same intensity and the LEDs are arranged over the panel so the light is homogeneous distributed over the subject.…”
Section: Physiology Of Tissue Perfusionmentioning
confidence: 99%
“…Healthy skin has a high pO2 level (8-13 kPa) but in tumors or hypoxic wounds the pO2 level can fall to 0.7 kPa [6;15]. Another process that can influence the skin pO2 is anesthesia, different type of anesthetics influence the skin perfusion in different ways [1]. …”
mentioning