2016
DOI: 10.4103/0970-9290.179836
|View full text |Cite
|
Sign up to set email alerts
|

Influence of different abutment diameter of implants on the peri-implant stress in the crestal bone: A Three-dimensional finite element analysis - In vitro study

Abstract: Results from this study showed the platform switched abutment led to relative decrease in von Mises stress in transcortical section of bone compared to normal abutment under vertical and oblique forces in posterior mandible region.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
10
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 0 publications
0
10
0
Order By: Relevance
“…10,11 In total, 4 models were made two for the "Simpli5y" and other two for "all-on-4." 10,11 In total, 4 models were made two for the "Simpli5y" and other two for "all-on-4."…”
Section: Numerical Modelling and Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…10,11 In total, 4 models were made two for the "Simpli5y" and other two for "all-on-4." 10,11 In total, 4 models were made two for the "Simpli5y" and other two for "all-on-4."…”
Section: Numerical Modelling and Analysismentioning
confidence: 99%
“…In this study, three-dimensional finite element models of maxilla, man- fixed, by constraining the movement of the peripheral nodes and the properties were given to the designed models to simulate the situation. 10,11 In total, 4 models were made two for the "Simpli5y" and other two for "all-on-4."…”
Section: Numerical Modelling and Analysismentioning
confidence: 99%
“…Von-Mises criteria were established within the methods because they are used in the scientific literature to study stress in fragile materials, such as bone (19). Oblique force loading was alter-natively implemented to axial loading because it represents the most harmful force to the implant system (20).…”
Section: Discussionmentioning
confidence: 99%
“…According to included studies 15,19,17,20,21,22,24,25,38 , there was a correlation between loading direction and stress level. The non-axial loads (oblique, horizontal) increased stresses on peri-implant bone compared to axial loads due to bending effect and shifting of load away from implant axis.…”
Section: Discussion:-mentioning
confidence: 99%
“…Despite the advantageous effect of platform switching on bone response, it increased stresses on implant prosthetic components which could result in mechanical complications such as screw loosening or fracture 16,27,21,22,23,26 .…”
mentioning