Abstract: This article presents the results of studies on the impact of the percentage of copper in the carbon composite of the railway pantograph contact strips on the maximum temperatures of the contact wire of the overhead contact line. The tests were carried out in accordance with the requirements of standards [7, 9] and TSI [4]. The obtained relationship allows for an initial assessment of the introduced materials due to the contact wire heating criterion based on the copper content of the carbon composite, which g… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…Although both the contact and the energy collection capabilities might be enhanced, it is also true that both systems suffer rapid wear. Several studies have been carried out to understand and measure the wear mechanism [1][2][3][4], and to develop new chemical compositions of OCW, shifting from pure copper to copper-based carbon composites [5][6][7]. In order to ensure railway service quality and safety, OCW wear measurements are required.…”
Section: Introductionmentioning
confidence: 99%
“…Although both the contact and the energy collection capabilities might be enhanced, it is also true that both systems suffer rapid wear. Several studies have been carried out to understand and measure the wear mechanism [1][2][3][4], and to develop new chemical compositions of OCW, shifting from pure copper to copper-based carbon composites [5][6][7]. In order to ensure railway service quality and safety, OCW wear measurements are required.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, to be able to select appropriate materials conforming to national conditions, it was necessary to carry out verification tests in accordance with normative requirements [16][17][18][19]. In our laboratory, we have also carried out numerous certification [20] and operational [21] tests to assess the quality of cooperation between carbon contact strips and copper contact wire on rolling stock operated in Poland. In these studies, special attention was paid to thermal issues.…”
Section: Introductionmentioning
confidence: 99%
“…As stated based on previous studies, the basic feature that affects the possibility of using a given contact strip is its electrical conductivity, which is directly determined by the amount of copper content in the carbon composite. Therefore, we earlier tested the concentration of metals used in contact wire and its effect on the resulting thermal resistance [21] as a basis for the current study.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation