2021
DOI: 10.1002/srin.202100332
|View full text |Cite
|
Sign up to set email alerts
|

Influence of Charging Parameters on the Burden Flow Velocity and Distribution on the Blast Furnace Chute Based on Discrete Element Method

Abstract: The ORCID identification number(s) for the author(s) of this article can be found under https://doi.org/10.1002/srin.202100332.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 33 publications
0
2
0
Order By: Relevance
“…After the DW-OAE 1 is pretrained, fW 1 , b 1 g is saved, and the MIC calculation is carried out to analyze the correlation of fh 1 1 , h 1 2 , : : : , h 1 N g with fy 1 , y 2 , : : : , y N g. Next, fh 1 1 , h 1 2 , : : : , h 1 N g are utilized to extract the second-level feature representations fh 2 1 , h 2 2 , : : : , h 2 N g, and update the parameter set fW 2 , b 2 g for DW-OAE 2. Here, assume the pretraining for DW-OAE k (k ¼ 1, 2, …, K À 1) has been completed, and the kth-level feature representations can be acquired by forward propagation.…”
Section: Dw-soaementioning
confidence: 99%
See 1 more Smart Citation
“…After the DW-OAE 1 is pretrained, fW 1 , b 1 g is saved, and the MIC calculation is carried out to analyze the correlation of fh 1 1 , h 1 2 , : : : , h 1 N g with fy 1 , y 2 , : : : , y N g. Next, fh 1 1 , h 1 2 , : : : , h 1 N g are utilized to extract the second-level feature representations fh 2 1 , h 2 2 , : : : , h 2 N g, and update the parameter set fW 2 , b 2 g for DW-OAE 2. Here, assume the pretraining for DW-OAE k (k ¼ 1, 2, …, K À 1) has been completed, and the kth-level feature representations can be acquired by forward propagation.…”
Section: Dw-soaementioning
confidence: 99%
“…Blast furnace (BF), a vital and energy-intensive unit, consumes more than half of energy and cost in the whole iron and steel manufacturing production process. [1][2][3] The energy consumption and operating status of BF are highly related to the gas flow distribution, fuel consumption, and so on. The gas utilization rate (GUR) represents the proportion of CO converted to CO 2 in the BF, which not only determines the rationality of gas flow distribution, but is also a concerned indicator for on-site operators to evaluate BF's energy consumption and operating status.…”
mentioning
confidence: 99%