2013
DOI: 10.1111/jopr.12058
|View full text |Cite
|
Sign up to set email alerts
|

Influence of Cement Film Thickness on the Retention of Implant‐Retained Crowns

Abstract: The results suggest that cement film thickness has an influence on the retentive strength of cemented implant-retained crowns.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
48
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(53 citation statements)
references
References 34 publications
4
48
0
1
Order By: Relevance
“…Since marginal fit is one of the most important determinants for the longevity of indirect restorations (18)(19)(20)(21), the cement film thickness is clinically critical. It has been documented that increasing the cement film thickness has a noticeable negative effect on the prosthesis retention (8). Accordingly, our results re-vealed that incorporating zinc oxide nanoparticles (in the mentioned weight fractions) into zinc phosphate or zinc polycarboxylate did not have any significant effect on their film thickness.…”
Section: Discussionsupporting
confidence: 68%
See 1 more Smart Citation
“…Since marginal fit is one of the most important determinants for the longevity of indirect restorations (18)(19)(20)(21), the cement film thickness is clinically critical. It has been documented that increasing the cement film thickness has a noticeable negative effect on the prosthesis retention (8). Accordingly, our results re-vealed that incorporating zinc oxide nanoparticles (in the mentioned weight fractions) into zinc phosphate or zinc polycarboxylate did not have any significant effect on their film thickness.…”
Section: Discussionsupporting
confidence: 68%
“…On the other hand, since the main disadvantage of conventional dental cements such as Zinc Polycarboxylate and Zinc Phosphate is their low mechanical strength (4,(7)(8)(9), nanoparticles can solve their shortcomings.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, a loaded shear force would be applied to the lateral surface of both the adhesive and bracket. Mehl et al (11) evaluated the effects of cement film thickness on retention of cemented implant-retained crowns and found that crown retention decreased significantly between cement films with thicknesses of 15 and 50 μm. Wakasa et al (17) reported that during a shear bond test the change in average stress with interfacial stress was related to the thickness of the bonding area.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, if the load applied by debonding pliers could be reduced, most of the remaining resin could be removed without pain. Mehl et al (11) reported that the thickness of the cement film affected the retentive strength of cementation in implant-retained crowns. We hypothesized that altering the thickness of the adhesive cement layer would reduce retentive strength (ie, the removal force required).…”
Section: Introductionmentioning
confidence: 99%
“…CAD/CAM sistemlerinin geliĢimiyle birlikte, özellikle implantüstü restorasyonlarda bar yapımı esnasında ya da metal destekli seramik restorasyonlar üre-tirken dökümden kaynaklanan büzülmeleri ve uyumsuzlukları engellemek ve pasif uyumu sağlamak amacıyla bu materyallerden üretilmiĢ bloklar kullanılır. 64 GeçmiĢten beri kullanılan geleneksel metal blokların yanı sıra güncel bir materyal olan sinterlenen …”
Section: Metallerunclassified