2014
DOI: 10.1152/japplphysiol.00752.2013
|View full text |Cite
|
Sign up to set email alerts
|

Influence of airway wall compliance on epithelial cell injury and adhesion during interfacial flows

Abstract: Higuita-Castro N, Mihai C, Hansford DJ, Ghadiali SN. Influence of airway wall compliance on epithelial cell injury and adhesion during interfacial flows. J Appl Physiol 117: 1231-1242, 2014. First published September 11, 2014 doi:10.1152/japplphysiol.00752.2013.-Interfacial flows during cyclic airway reopening are an important source of ventilator-induced lung injury. However, it is not known how changes in airway wall compliance influence cell injury during airway reopening. We used an in vitro model of airw… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
28
1
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 30 publications
(33 citation statements)
references
References 48 publications
3
28
1
1
Order By: Relevance
“…As described in our previous studies [17] and shown schematically in Fig 1, a Bioptechs FCS2 chamber (Bioptechs, Butler, PA) and a programmable PHD 2000 syringe pump (Harvard Apparatus, Holliston, MA) were used to expose cells to cyclic airway reopening conditions. Briefly, confluent samples were placed inside the chamber and the flow channel (35mm length, 10mm width, and 0.5mm height) was filled with phosphate-buffered saline (PBS).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…As described in our previous studies [17] and shown schematically in Fig 1, a Bioptechs FCS2 chamber (Bioptechs, Butler, PA) and a programmable PHD 2000 syringe pump (Harvard Apparatus, Holliston, MA) were used to expose cells to cyclic airway reopening conditions. Briefly, confluent samples were placed inside the chamber and the flow channel (35mm length, 10mm width, and 0.5mm height) was filled with phosphate-buffered saline (PBS).…”
Section: Methodsmentioning
confidence: 99%
“…Silicon nitride cantilevers with a nominal spring constant k = 0.01 N/m, length of 200 μm, and a regular four-sided pyramidal tip with an angle θ= 35° were used for these measurements (Veeco, Santa Barbara CA). Following protocols previously reported by our group [17, 34], 5–12 regions per sample were scanned in contact mode and the deflection error and height image was recorded. Height images were analyzed with the NanoScope Analysis software package (Bruker Instruments, Camarillo CA) to measure cell height, width and length.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…In order to relate the parameters F s , F t , and k to dimensional values, we computed a reference force scale f based on Young’s modulus, E , of an alveolar epithelial cell, which has been measured with atomic-force microscopy to be around 1–5 kPa for human A549 cells in a confluent monolayer. 2,15,27 For this model, we assumed E = 1 kPa for the entire spring network. We simulated horizontal stretch of the 45-cell network and used the stress-strain relation E = σ/ε, where σ = f F s / A I (the applied force adjusted by the scaling force divided by the initial cross-sectional area over which the force is applied) and ε = Δ L / L 0 (the linear displacement of the network due to the force relative to its initial length), to compute the scaling force f for F s that yielded E = 1 kPa.…”
Section: Methodsmentioning
confidence: 99%