2005
DOI: 10.1016/j.ijms.2004.11.009
|View full text |Cite
|
Sign up to set email alerts
|

Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS for isotope analysis of long-lived radionuclides

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
54
0
1

Year Published

2006
2006
2013
2013

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 111 publications
(57 citation statements)
references
References 85 publications
1
54
0
1
Order By: Relevance
“…The review by Todorov and coworkers was concerned with measurement of depleted uranium, but the same methods are applicable to natural or enriched uranium. Use of ICP-MS for analysis of uranium in bioassay samples has increased considerably in recent years (Becker 2005). Advantages of this method compared with other common techniques such as alpha spectrometry include some or all of the following: high sensitivity, low cost, ease of sample preparation, and short analysis time (Karpas et al 1996;Maxell and Fauth 2002;Hang et al 2004;Bouvier-Capely et al 2004;Becker 2005).…”
Section: A31 In Vitro Measurement Of Uraniummentioning
confidence: 99%
“…The review by Todorov and coworkers was concerned with measurement of depleted uranium, but the same methods are applicable to natural or enriched uranium. Use of ICP-MS for analysis of uranium in bioassay samples has increased considerably in recent years (Becker 2005). Advantages of this method compared with other common techniques such as alpha spectrometry include some or all of the following: high sensitivity, low cost, ease of sample preparation, and short analysis time (Karpas et al 1996;Maxell and Fauth 2002;Hang et al 2004;Bouvier-Capely et al 2004;Becker 2005).…”
Section: A31 In Vitro Measurement Of Uraniummentioning
confidence: 99%
“…ICP-MS has been used to determine 129 I in contaminated environmental samples with high level 129 I content such as sediments, groundwater samples, soil and seaweed (Izmer et al, 2003;Izmer et al, 2004;Becker, 2005;Brown et al, 2007;Li et al, 2009). The lowest detection limit of the method reported as 129 I/ 127 I isotopic ratio is 10 -7 .…”
Section: Inductively Coupled Plasma Mass Spectrometry (Icp-ms)mentioning
confidence: 99%
“…Inductively coupled plasma mass spectrometry (ICP/MS) has been increasingly used for precise and accurate determination of isotope ratios of long-lived radionuclides at the trace and ultratrace level due to its excellent sensitivity, good precision and accuracy [Becker, 2005]. An X series using Plasma Hot Screen (Thermo Electron Corp., USA) was used in this study for qualitative analysis of SRS DNAPL.…”
Section: Inorganic Compositionsmentioning
confidence: 99%