Abstract: The first sections of this article describe a brief history, the basic principles and advantages as well as disadvantages of inductively coupled plasma mass spectrometry (ICPMS) over other analytical techniques commonly used for environmental analysis (see Figure 1). Section 4 is devoted to the discussion of the relative merits and demerits of a wide variety of dissolution techniques and their limitation in the pretreatment of various environmental samples. In section 5, efforts are concentrated on the novel a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2001
2001
2023
2023

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 12 publications
(15 citation statements)
references
References 120 publications
0
15
0
Order By: Relevance
“…This type of ICP-MS is equipped with a doublefocusing mass spectrometer to separate the analyte ions from the overlapping polyatomic ions originating from gaseous components and/or matrix elements. The commonly used quadrupole-type ICP-MS does not enable to separate chemically different ions with the same nominal mass values and, therefore, is more prone to give inaccurate results, especially when the concentrations of the analytes are low (Yamasaki 1996(Yamasaki ,2000. For the latter instrument, a special attachment (capacitive decoupling device) was installed to enhance ion transmission by suppressing the secondary discharge.…”
Section: Methodsmentioning
confidence: 99%
“…This type of ICP-MS is equipped with a doublefocusing mass spectrometer to separate the analyte ions from the overlapping polyatomic ions originating from gaseous components and/or matrix elements. The commonly used quadrupole-type ICP-MS does not enable to separate chemically different ions with the same nominal mass values and, therefore, is more prone to give inaccurate results, especially when the concentrations of the analytes are low (Yamasaki 1996(Yamasaki ,2000. For the latter instrument, a special attachment (capacitive decoupling device) was installed to enhance ion transmission by suppressing the secondary discharge.…”
Section: Methodsmentioning
confidence: 99%
“…In was used as an internal standard element (Yamasaki 1996;Yamasaki 2000). For the determination of In, however, rhodium (Rh) was used as an internal standard element.…”
Section: Icp-ms Measurementmentioning
confidence: 99%
“…Rock powders were prepared in a tungsten-carbide mill at Kyoto University and samples were prepared by acid digestion after alkali fusion. Indium was used for an internal standard (Yamasaki, 1996;Yamasaki et al, 2013).…”
Section: Methodsmentioning
confidence: 99%