2011
DOI: 10.1021/ja205996e
|View full text |Cite
|
Sign up to set email alerts
|

Induced Self-Assembly and Förster Resonance Energy Transfer Studies of Alkynylplatinum(II) Terpyridine Complex Through Interaction With Water-Soluble Poly(phenylene ethynylene sulfonate) and the Proof-of-Principle Demonstration of this Two-Component Ensemble for Selective Label-Free Detection of Human Serum Albumin

Abstract: The interaction of conjugated polyelectrolyte, PPE-SO(3)(-), with platinum(II) complexes, [Pt(tpy)(C≡CC(6)H(4)-CH(2)NMe(3)-4)](OTf)(2) (1) and [Pt(tpy)(C≡C-CH(2)NMe(3))](OTf)(2) (2), has been studied by UV-vis, and steady-state and time-resolved emission spectroscopy. A unique FRET from PPE-SO(3)(-) to the aggregated complex 1 on the polymer chain with Pt···Pt interaction has been demonstrated, resulting in the growth of triplet metal-metal-to-ligand charge transfer ((3)MMLCT) emission in the near-infrared (NI… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

6
116
0

Year Published

2013
2013
2017
2017

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 144 publications
(122 citation statements)
references
References 74 publications
6
116
0
Order By: Relevance
“…20 These complexes have attracted much attention due to their luminescence properties and their potential applications in chemical sensing and biosensing. [21][22][23][24] For example, an alkynylplatinum(II) terpyridine complex has been reported to detect human serum albumin (HSA). 22 Cl] + (70.1 mM) and LPS (3.0 mM) was transferred into a cuvette, and the particle size was measured at room temperature.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…20 These complexes have attracted much attention due to their luminescence properties and their potential applications in chemical sensing and biosensing. [21][22][23][24] For example, an alkynylplatinum(II) terpyridine complex has been reported to detect human serum albumin (HSA). 22 Cl] + (70.1 mM) and LPS (3.0 mM) was transferred into a cuvette, and the particle size was measured at room temperature.…”
Section: Introductionmentioning
confidence: 99%
“…[21][22][23][24] For example, an alkynylplatinum(II) terpyridine complex has been reported to detect human serum albumin (HSA). 22 Cl] + (70.1 mM) and LPS (3.0 mM) was transferred into a cuvette, and the particle size was measured at room temperature. For the atomic force microscope (AFM) imaging, the above solution was spun-coated onto a piece of clean silicon wafer to disperse the LPS-Pt(II) aggregates.…”
Section: Introductionmentioning
confidence: 99%
“…Earlier work by our group showed the first example, to our knowledge, of an alkynylplatinum(II) terpyridine system [Pt(tpy)(C ≡ CR)] + that incorporates σ-donating and solubilizing alkynyl ligands together with the formation of Pt···Pt interactions to exhibit notable color changes and luminescence enhancements on solvent composition change (25) and polyelectrolyte addition (26). This approach has provided access to the alkynylplatinum(II) terpyridine and other related cyclometalated platinum(II) complexes, with functionalities that can self-assemble into metallogels (27)(28)(29)(30)(31), liquid crystals (32,33), and other different molecular architectures, such as hairpin conformation (34), helices (35)(36)(37)(38), nanostructures (39)(40)(41)(42)(43)(44)(45), and molecular tweezers (46,47), as well as having a wide range of applications in molecular recognition (48)(49)(50)(51)(52), biomolecular labeling (48)(49)(50)(51)(52), and materials science (53,54). Recently, metalcontaining amphiphiles have also emerged as a building block for supramolecular architectures (42)(43)(44)(55)(56)(57)…”
mentioning
confidence: 99%
“…Emission lifetimes were similar at various wavelengths sampled across the observed emission manifold, and decays were fit by a single exponential model. It should be noted that the measured lifetime for 7 is approaching the FWHM of our excitation laser (10 ns), suggesting that the lifetime is likely shorter than recorded (similar PPE-type polymer samples typically have fluorescence lifetimes around 1 ns) [40,[54][55][56]. The fullerene-containing samples have distinctly longer lifetimes than 7 but are still relatively short.…”
Section: Emission Spectroscopymentioning
confidence: 69%