2021
DOI: 10.1039/d1qi00209k
|View full text |Cite
|
Sign up to set email alerts
|

Induced fit activity-based sensing: a mechanistic study of pyrophosphate detection with a “flexible” Fe-salen complex

Abstract: Activity-based sensing of biological targets is attracting increasing attention. In this work, we report detailed UV-Vis and fluorescence mechanistic studies on an Fe-salen based probe, [FeIII{salenMeCl2(SO3)2}OH2]- for pyrophosphate (PPi) detection....

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
26
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(26 citation statements)
references
References 56 publications
0
26
0
Order By: Relevance
“…For long time, the selectivity of 11 for PPi over ATP and other potential interferents posed a riddle. This mystery was tackled by Zelder, Roodt and coworkers in detailed kinetic studies with absorbance and fluorescence spectroscopy supported by computational studies [72] . Overall, the PPi‐induced disassembly follows a pseudo‐first order reaction with a half‐life of ca.…”
Section: Mechanism Of Disassembly Of Fe(iii)‐salen Complexesmentioning
confidence: 99%
See 2 more Smart Citations
“…For long time, the selectivity of 11 for PPi over ATP and other potential interferents posed a riddle. This mystery was tackled by Zelder, Roodt and coworkers in detailed kinetic studies with absorbance and fluorescence spectroscopy supported by computational studies [72] . Overall, the PPi‐induced disassembly follows a pseudo‐first order reaction with a half‐life of ca.…”
Section: Mechanism Of Disassembly Of Fe(iii)‐salen Complexesmentioning
confidence: 99%
“…The overall disassembly reaction consists of two subsequent equilibria and one final irreversible reaction (Figure 10). [72] …”
Section: Mechanism Of Disassembly Of Fe(iii)‐salen Complexesmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, an alternative sensing approach combining the well-known displacement assay (i.e., displacement of the metal cation upon PPi binding) [10,14] to a ligand hydrolysis reaction, has been developed. Thus, Zelder and co-workers pioneered metal-salen-based probes that detect PPi anions via a "turn-on" fluorogenic response arising from a molecular disassembly process that releases fluorescent salicylaldehyde [15][16][17][18][19], [20] (Fig. 1).…”
Section: Introductionmentioning
confidence: 99%
“…H-,13 C and19 F NMR spectra were recorded on a Bruker Avance 400 MHz spectrometer.Chemical shifts (d) were reported in ppm and residual non-deuterated solvent peaks were used as internal reference (proton d = 7.26 and carbon d = 77.16 for CDCl3, proton d = 2.50 and carbon d = 39.52 for DMSO-d6, and proton d = 3.31 and carbon d = 49.00 for CD3OD)[30].No internal standard was used for 19 F{ 1 H} NMR. 1 H NMR coupling constants (J) are reported in Hertz (Hz).…”
mentioning
confidence: 99%