2006
DOI: 10.2298/fupct0601093b
|View full text |Cite
|
Sign up to set email alerts
|

Indoor radon measurements by nuclear track detectors: Applications in secondary schools

Abstract: Indoor radon measurements by nuclear track detectors and application of the method in secondary schools in Serbia were performed in the spring 2004. Thirty detectors (type CR-39) were distributed to high school teachers in several cities in Serbia. After three months of the detectors exposure, they were sent back to the Low- Level Laboratory, Institute of Physics, Belgrade. After exposure, the CR-39 detectors were etched in a 6N NaOH at 700C for 3 hours. The tracks were counted by the semiautomatic track-count… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
13
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(14 citation statements)
references
References 5 publications
1
13
0
Order By: Relevance
“…Radon monitoring in the underground low-background laboratory with the passive and active devices [16]; radon laboratory for chemical etching of the track detectors and automatic counting of the tracks by optical microscopy [17]; modelling of the indoor radon behaviour [18].…”
Section: University Of Belgrade Institute Of Physics Belgrade Low-bmentioning
confidence: 99%
“…Radon monitoring in the underground low-background laboratory with the passive and active devices [16]; radon laboratory for chemical etching of the track detectors and automatic counting of the tracks by optical microscopy [17]; modelling of the indoor radon behaviour [18].…”
Section: University Of Belgrade Institute Of Physics Belgrade Low-bmentioning
confidence: 99%
“…The signal measured by etched-track dosimeters is the integrated track density, ρ (tracks cm-2). If the track density is uniform over the detector surface, the signal is defined by [12]…”
Section: Radon Concentration and Exhalation Ratementioning
confidence: 99%
“…where dρ/dt is the track density production rate (track cm -2 h -1 ). For diffusion chamber type dosimeter with a long exposure time, the response can be approximated by [12] and [13].…”
Section: Radon Concentration and Exhalation Ratementioning
confidence: 99%
“…The mon i tor ing of in door ra don lev els in school build ings as well as houses and of fices is very im por tant for an ad e quate ra dio log i cal risk as sess ment for stu dents and staff. In the past de cade, sev eral sys tem atic ra don sur veys were car ried out in school build ings all over the world [5][6][7][8][9][10][11][12][13][14][15][16] but few data are avail able re gard ing the pres ence of ra don in schools in Tur key [17][18][19]. In general, the ra don sur vey in schools was per formed us ing the pas sive track etch ing with solid state nu clear de tec tors type CR-39 and LR-115.…”
Section: Introductionmentioning
confidence: 99%