2009
DOI: 10.1016/j.atmosenv.2009.08.031
|View full text |Cite
|
Sign up to set email alerts
|

Indoor–outdoor concentrations of RSPM in classroom of a naturally ventilated school building near an urban traffic roadway

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

6
50
1
1

Year Published

2011
2011
2023
2023

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 105 publications
(58 citation statements)
references
References 33 publications
6
50
1
1
Order By: Relevance
“…Fromme et al (2008) also noted that the physical activity of pupils leads to the resuspension of indoor coarse particles, and is the main reason for rises in the level of PM 10 in classrooms. This relationship was also highlighted by Goyal and Khare (2009), who carried out a study on indoor-outdoor PM concentrations by monitoring a classroom in a naturally ventilated school building located near an urban roadway in Delhi City (India). The results showed that half-hourly average indoor PM 10 concentrations were highest when the students were most active in the room.…”
Section: Introductionmentioning
confidence: 99%
“…Fromme et al (2008) also noted that the physical activity of pupils leads to the resuspension of indoor coarse particles, and is the main reason for rises in the level of PM 10 in classrooms. This relationship was also highlighted by Goyal and Khare (2009), who carried out a study on indoor-outdoor PM concentrations by monitoring a classroom in a naturally ventilated school building located near an urban roadway in Delhi City (India). The results showed that half-hourly average indoor PM 10 concentrations were highest when the students were most active in the room.…”
Section: Introductionmentioning
confidence: 99%
“…These concentrations were about 100 times higher than the WHO standard (60-90 µg m ) [29]. A study in school classrooms in Delhi reported indoor PM 10 , PM 2.5 and PM 1.0 concentrations 3.59 ± 1.81, 2.79 ± 1.6, 2.18 ± 0.70 times higher than outdoors in summer, and 2.83 ± 1.14, 1.60 ± 0.17, 1.52 ± 0.15 times higher in winters, respectively [25]. The available evidences clearly indicate that the IAQ is an equally important issue in India as outdoor air quality.…”
Section: Iaq -Is It As Important Issue As Outdoor Air Quality?mentioning
confidence: 99%
“…Compared with research reviewed in the developed world [15][16][17][18][19][20][21][22][23], only a handful of studies has investigated the IAQ in urban indoor settings in India [24][25][26][27][28]. Most of the so far conducted research is either limited to individual studies or based on short-term measurements that suffer from a small sample size.…”
Section: Introductionmentioning
confidence: 99%
“…A number of studies reported to have high levels of PM 10 and PM 2.5 in the classrooms (Alves et al, 2013;Heudorf et al, 2009;Goyal and Khare, 2009) with a wide range varying from 13 to 1181.1 µg/m 3 and 13.5 to 359.9 µg/m 3 , respectively. However, this present study concentration is not as high as other developing countries due to multiple factors as the school in Malaysia has complex indoor environment, which differ in location, geographical area, weather or seasonal variation and building design.…”
Section: Had Done Two Times Measurement In 2008mentioning
confidence: 99%