2014
DOI: 10.1016/j.ijrefrig.2013.11.023
|View full text |Cite
|
Sign up to set email alerts
|

Indoor leakage test for safety of R-290 split type room air conditioner

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 51 publications
(8 citation statements)
references
References 3 publications
0
6
0
Order By: Relevance
“…Other work (e.g. Jabbour and Clodic, 2008;Zhang et al, 2013;Li, 2014) involving measurements of room floor concentrations (𝐶 𝑓𝑙𝑜𝑜𝑟 ) due to releases of R290 (propane) from AC units were shown to be significantly lower than what was inferred by the formula (used in IEC 60335-2-40), provided the release height was above around 0.6 m from the floor. It is noted that the formula used an assumption of fixed flammable volume-time and except for the general information that this was quantified using CFD, no details of their calculation procedures were given.…”
Section: Introductionmentioning
confidence: 90%
“…Other work (e.g. Jabbour and Clodic, 2008;Zhang et al, 2013;Li, 2014) involving measurements of room floor concentrations (𝐶 𝑓𝑙𝑜𝑜𝑟 ) due to releases of R290 (propane) from AC units were shown to be significantly lower than what was inferred by the formula (used in IEC 60335-2-40), provided the release height was above around 0.6 m from the floor. It is noted that the formula used an assumption of fixed flammable volume-time and except for the general information that this was quantified using CFD, no details of their calculation procedures were given.…”
Section: Introductionmentioning
confidence: 90%
“…It has been widely reported that the ACL formula in IEC 60335-2-40 is restrictive when applying it to common room air conditioning and air-to-air heat pump systems (e.g., Corberan et. al, 2008;Li, 2014;Vonsild, 2012;Zhang et. al., 2013).…”
Section: Limits For Air Conditioners and Heat Pumps/ "Comfort" Applicationsmentioning
confidence: 99%
“…80 Some of these refrigerants, however, give rise to flammability and safety hazards issues. 81,82 In supermarket applications, for example, one way to overcome such a situation (ie, flammable and toxic refrigerant circulating within the supermarket premises) is to operate with an indirect refrigeration system, 83 where the refrigerant loop is confined to a remotely located machine room, thus allowing for better safety hazard control and a significant reduction on refrigerant charge. Supermarket public areas (with refrigerated display cases, walk-in coolers, and freezers, and so on) are then served through a secondary fluid loop, 84 in which coolant fluids such as water or aqueous mixtures have an important role due to the nominal values of their thermophysical properties.…”
Section: Characterization Of Nanofluid Imentioning
confidence: 99%