2010
DOI: 10.1089/lrb.2010.0005
|View full text |Cite
|
Sign up to set email alerts
|

Indocyanine Green and Lymphatic Imaging: Current Problems

Abstract: Background: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) has recently been presented as a comparatively easy and informative technique to image lymphatic channels in vivo. However, no data or references have been provided concerning the impact of ICG application on normal lymphatic contractility and lymph transport. Thus, the imaging agent and/or the method of administration may introduce a significant artifact. Methods and Results: Standard pharmacological tests were performed to inv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
44
3

Year Published

2011
2011
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 52 publications
(48 citation statements)
references
References 18 publications
1
44
3
Order By: Relevance
“…It is likely that the published results by another group 17 showing changes in lymphatic function with varying ICG concentrations could be attributed to the use of very different experimental conditions than ours. The other group perfused ICG through ex vivo isolated mesenteric rat vessels at a fixed pressure and an imposed flow, while our studies noninvasively measured murine in vivo peripheral, inguinal-to-axillary postnodal efferent transport.…”
contrasting
confidence: 53%
See 1 more Smart Citation
“…It is likely that the published results by another group 17 showing changes in lymphatic function with varying ICG concentrations could be attributed to the use of very different experimental conditions than ours. The other group perfused ICG through ex vivo isolated mesenteric rat vessels at a fixed pressure and an imposed flow, while our studies noninvasively measured murine in vivo peripheral, inguinal-to-axillary postnodal efferent transport.…”
contrasting
confidence: 53%
“…In our studies using a mouse model that simulates our human studies, ICG concentration, as well as the use of other NIR fluorophores, did not affect lymphatic function. Using this NIR technique developed in our laboratories, we have shown its use to direct therapy 17 as well as to detect improvement in lymphatic function immediately after therapy. 6,8 Noninvasive methods to investigate the lymphatic system can provide new avenues to discovery, diagnosis, and emerging therapies of lymphatic disorders and diseases.…”
mentioning
confidence: 99%
“…Additional concerns were raised by the possibility that indocyanine green dye injection stimulates lymphatic smooth muscle contractions. 153 Nevertheless, nearinfrared imaging will likely soon allow better functional characterization of the various forms of lymphedema and more precise mapping of sentinel lymph nodes. Immunopositron emission tomography with radioactively labeled antibodies against LEC surface antigens such as LYVE-1 enables early visualization of tumor-and lymph nodeassociated lymphangiogenesis.…”
Section: Lymphatic Imagingmentioning
confidence: 99%
“…Several studies have sought to characterize how some experimental parameters affect lymphatic functional measurements. These include studies that explored the effect of tracer type and size (13), ICG concentration (22), and whether the fluorophore, time after injection, and vessel selection alter the measurements (23). However, these studies did not compare different measurement techniques.…”
Section: Introductionmentioning
confidence: 99%