Individual monitoring of hearing status: Development and validation of advanced techniques to measure otoacoustic emissions in suboptimal test conditions

Abstract: Scientific evidence suggests that measurement of otoacoustic emissions (OAE) is a reliable tool to detect the early onset of noise induced hearing loss. Nevertheless, the individual field measurement of otoacoustic emissions on industrial workers is very challenging in practice because the high level of ambient noise usually disturbs the OAE measurement. The use of OAE measurement probes with high passive noise isolation allows the attenuation of most of the high frequency ambient noise, but it is often insuff… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 20 publications
0
5
0
2
Order By: Relevance
“…The transfer function between the OEM and IEM is calculated to remain as close as possible to realistic conditions. This is achieved by playing white noise over loudspeakers in the audiometric booth while the speaker is still equipped with the in-ear HPD [13]. The noise signals collected by the IEM and OEM are then used to calculate the transfer function between the two microphones, i.e.…”
Section: Measuing the Transfer Function Of The Earpiecementioning
confidence: 99%
“…The transfer function between the OEM and IEM is calculated to remain as close as possible to realistic conditions. This is achieved by playing white noise over loudspeakers in the audiometric booth while the speaker is still equipped with the in-ear HPD [13]. The noise signals collected by the IEM and OEM are then used to calculate the transfer function between the two microphones, i.e.…”
Section: Measuing the Transfer Function Of The Earpiecementioning
confidence: 99%
“…The artificial generator therefore has to be regarded as representative for a single individual drawn from the population. The DPOAE generator can support the development of hardware and software solutions that allow extending the range of tolerable background noise levels [7]. This would enabling robust DPOAE acquisition in even harsher measurement environments.…”
Section: Discussionmentioning
confidence: 99%
“…This example shows that improvements in OAE equipment can have a substantial influence on the final DPOAE amplitudes. This is also important outside routine clinical conditions, where constantly advancements are being made to enable DPOAE acquisition in suboptimal test conditions [7,27,28].…”
Section: Discussionmentioning
confidence: 99%