Abstract:Indium tin oxide (ITO) CMP was performed by change of de-ionized water (DIW)
temperature in pad conditioning process. DIW with high temperature was employed in pad
conditioning immediately before ITO-CMP. The removal rate of ITO thin film polished by silica
slurry immediately after pad conditioning process with the different DIW temperatures dramatically
increased to 93.0 nm/min after pad conditioning at DIW of 75 oC, while that after the general
conditioning process at 30 oC was about 66.1 nm/min. The grains … Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.