Independent Electromagnetic Field Control for Practical Approach to Actively Locomotive Wireless Capsule Endoscope

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
22
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

5
4

Authors

Journals

citations
Cited by 64 publications
(25 citation statements)
references
References 43 publications
0
22
0
Order By: Relevance
“…Based on the Helmholtz and Maxwell coil configuration, we built the system with a barrel shape so that the patient could easily access it. Figure 1 shows the conceptual design of the system, and a detailed configuration can be found in our previous development [44]. To guarantee a powerful system, we used 10 electromagnets including a pair of Helmholtz coils, 2 pairs Maxwell coils, and 2 pairs of rectangle coils.…”
Section: Active Control Through Electromagnetic Actuationmentioning
confidence: 99%
See 1 more Smart Citation
“…Based on the Helmholtz and Maxwell coil configuration, we built the system with a barrel shape so that the patient could easily access it. Figure 1 shows the conceptual design of the system, and a detailed configuration can be found in our previous development [44]. To guarantee a powerful system, we used 10 electromagnets including a pair of Helmholtz coils, 2 pairs Maxwell coils, and 2 pairs of rectangle coils.…”
Section: Active Control Through Electromagnetic Actuationmentioning
confidence: 99%
“…In our previous study [44], 𝑩 𝑭 was defined by six parameters. As an advancement from the previous study, we newly present an end-user-oriented control algorithm in this paper.…”
Section: Active Control Through Electromagnetic Actuationmentioning
confidence: 99%
“…where D = [B F] T denotes the desired matrix and M u ∈ R 12×4 denotes the unit matrix corresponding to the four coils in the range of the ROI. To obtain the value of the input current in (8), matrix inversion is applied to M u , and a pseudo inversion is applied to obtain the current matrix via the following equation in analogy with the methodology of [30].…”
Section: Ffp Generationmentioning
confidence: 99%
“…Various methodologies for robotic capsule endoscope (RCE) localization have been comprehensively studied to date. Posture information provided by the localization system, such as the feedback control achieved by incorporating an external magnetic actuation (EMA) system, can significantly enhance the performance of an RCE [1][2] [3]. However, the existing localization system is still in a state of underdevelopment, owing to limitations such as a narrow workspace, low accuracy, and slow response time.…”
Section: Introductionmentioning
confidence: 99%