2020 7th International Conference on Energy Efficiency and Agricultural Engineering (EE&AE) 2020
DOI: 10.1109/eeae49144.2020.9279107
|View full text |Cite
|
Sign up to set email alerts
|

Increasing the energy efficiency of fan systems by using outlet diffuser

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 4 publications
0
2
0
Order By: Relevance
“…As mentioned in the Introduction, the use of a diffuser installed at the outlet of a fan system can improve the system energy efficiency. In accordance with [3], the reduction of specific fan power ∆SFP when using a diffuser installed at the system output and achieving the initial operating mode after VFD flow regulation is applied, may be determined using the following equation:…”
Section: Analysis Of the Results Obtainedmentioning
confidence: 99%
See 1 more Smart Citation
“…As mentioned in the Introduction, the use of a diffuser installed at the outlet of a fan system can improve the system energy efficiency. In accordance with [3], the reduction of specific fan power ∆SFP when using a diffuser installed at the system output and achieving the initial operating mode after VFD flow regulation is applied, may be determined using the following equation:…”
Section: Analysis Of the Results Obtainedmentioning
confidence: 99%
“…Studies concerning the determination of the impact of the geometric features of conical diffusers on reducing the consumption of fan systems are presented in [2] and [3]. Often, air ducts, used in ventilation systems, are designed with a rectangular cross-section.…”
Section: Introductionmentioning
confidence: 99%
“…To realize the high-speed operation of the valve and the displacement of the spool, high power of the controlled spool and high electrical power consumption are required. The technical solution for the pneumatic high-speed valve to have a powerful coil 80 W; 24 VDC which enables the fast control [8]. Once the pneumatic valve is energized at 24 VDC, its spool is moved to switch from the "OFF" position to the "ON" position, but to hold it in this position usually not the full power is needed, but only part of it to hold the spool in the operating position, usually this is 70/75% less power than the rated Fig.…”
Section: Methodsmentioning
confidence: 99%