2006
DOI: 10.1016/j.cca.2006.05.019
|View full text |Cite
|
Sign up to set email alerts
|

Inclusion of MPA and in a rapid multi-drug LC–tandem mass spectrometric method for simultaneous determination of immunosuppressants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
26
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 44 publications
(27 citation statements)
references
References 14 publications
1
26
0
Order By: Relevance
“…The LOQ corresponded to a concentration of 0.72 mg/mL, as previously defined. If we consider a typical range of the 0-12 h AUC curve (7.3-102.3 mg/h/mL) [31], the obtained RSD value was below 15%, comparable to those reported by other authors for HPLC methods [34]. …”
Section: Assessment Of Performance Characteristicssupporting
confidence: 79%
“…The LOQ corresponded to a concentration of 0.72 mg/mL, as previously defined. If we consider a typical range of the 0-12 h AUC curve (7.3-102.3 mg/h/mL) [31], the obtained RSD value was below 15%, comparable to those reported by other authors for HPLC methods [34]. …”
Section: Assessment Of Performance Characteristicssupporting
confidence: 79%
“…Some salient features of the method included: (a) adequate chromatographic separation between MPAG and MPA to avoid in-source cross-talk owing to fragmentation of MPAG to MPA by the use of a POROS pre-column, which also helped in matrix cleanup; (b) the use of cyclosporine D as IS for both MPA and MPAG; (c) efficient optimization of the ionization interfering effects owing to MPAG as a result of solvent change in the column switching program; and (d) adoptability of the method for quantitation of MPA and other immunosuppressant drugs in a single run after column switching to exclude MPAG (Ceglarek et al, 2006). Difrancesco et al (2007 have developed a LC-MS/MS assay for measuring MPA and MPAG along with cortisol, dexamethasone, methylprednisolone, prednisone and prednisolone, which are also part of immunosuppressive therapy in transplantation patients.…”
Section: Measurement Of Mpa In Vitreous Humormentioning
confidence: 99%
“…This allows a flow of up to 5 mL/min during extraction at a back pressure <100 bar. As a result on-line sample preparation can be adapted to high throughput conditions [32][33][34]. Advantages of this approach are the possibilities for identification and quantification, high analytical detection power, as well as high accuracy and reproducibility.…”
Section: Spementioning
confidence: 99%