2017
DOI: 10.1016/j.molliq.2017.04.098
|View full text |Cite
|
Sign up to set email alerts
|

Inclusion complex of antiasthmatic compound with 2-hydroxypropyl-β-cyclodextrin: Preparation and physicochemical properties

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
17
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(18 citation statements)
references
References 24 publications
1
17
0
Order By: Relevance
“…The absorption peak of DSL at 165.18°C disappeared in the inclusion complex thermograms (Figure 4c-e). Complete absence of the melting endotherm of the active agent implies amorphization of the crystalline substance in the presence of an amorphous structure and verifies constitution of inclusion complex [7,9,11].…”
Section: Differential Scanning Calorimetry (Dsc)mentioning
confidence: 98%
See 3 more Smart Citations
“…The absorption peak of DSL at 165.18°C disappeared in the inclusion complex thermograms (Figure 4c-e). Complete absence of the melting endotherm of the active agent implies amorphization of the crystalline substance in the presence of an amorphous structure and verifies constitution of inclusion complex [7,9,11].…”
Section: Differential Scanning Calorimetry (Dsc)mentioning
confidence: 98%
“…DSC is an important analytical technique for the analysis of solid materials as it can supply exhaustive information on their physical and energy characteristics [32]. DSC is therefore commonly utilized to investigate the interactions between drug substances and CDs in solid form [11]. We can elicit about solidstate modifications and interactions between the components and verify complexation mechanism by comparison with the thermograms of individual constituents, their physical blend and the prepared inclusion complexes.…”
Section: Differential Scanning Calorimetry (Dsc)mentioning
confidence: 99%
See 2 more Smart Citations
“…Differential scanning calorimetry (DSC) is a validated tool for studying the thermodynamic changes and the interactions that occur between tested components. 54 The DSC thermographs of pure SMV, HP β-CD, their physical mixture and the freeze-dried inclusion complex are illustrated in Figure 3. The thermogram of pure SMV revealed a sharp endothermic peak at 141.35°C indicating the crystallinity of the drug, while the thermogram of HP β-CD showed a short broad endothermic peak between 50°C and 110°C.…”
Section: Physicochemical Characterization Of Smv-hp β-Cd Icmentioning
confidence: 99%