1999
DOI: 10.1016/s0195-6701(99)90067-1
|View full text |Cite
|
Sign up to set email alerts
|

Inactivation of prions by physical and chemical means

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
113
0
3

Year Published

2001
2001
2022
2022

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 181 publications
(118 citation statements)
references
References 30 publications
2
113
0
3
Order By: Relevance
“…Drawbacks in actual sterilization processes are related in particular to the high resistance of certain biomolecules, for instance prions, towards routine chemical and physical cleaning processes [3] or incompatibility between the materials used in biomedical applications and the process parameters [4][5][6]. Infectious proteins, i.e.…”
Section: Introductionmentioning
confidence: 99%
“…Drawbacks in actual sterilization processes are related in particular to the high resistance of certain biomolecules, for instance prions, towards routine chemical and physical cleaning processes [3] or incompatibility between the materials used in biomedical applications and the process parameters [4][5][6]. Infectious proteins, i.e.…”
Section: Introductionmentioning
confidence: 99%
“…The high resistance of TSE agents to conventional methods of chemical or thermal inactivation and to UV or ionizing radiation (Alper et al, 1966(Alper et al, , 1967Brown et al, 1982Brown et al, , 1986Kimberlin et al, 1983;Taguchi et al, 1991;Tateishi et al, 1991;Ernst & Race, 1993;Taylor et al, 1994;Manuelidis, 1997;Taylor, 1999; for review see Taylor, 2000), as well as their high binding affinity to and tenacity on steel surfaces (Zobeley et al, 1999;Flechsig et al, 2001), warrant specific decontamination procedures in the reprocessing of surgical instruments (Rutala & Weber, 2001). Treatments that are considered appropriate for decontamination include use of 1-2 M NaOH solution (for 24 h), 2?5-5 % NaOCl solution (for 24 h) as well as 3, 4 or 6 M GdnSCN solution (for 24 h, 1 h or 15 min, respectively), followed by steam sterilization at 134 u C for 18 min to 1 h (Simon & Pauli, 1998;World Health Organization, 1999;Hörnlimann et al, 2001).…”
Section: Introductionmentioning
confidence: 99%
“…18 It is, therefore, important that the dental profession gives serious thought to provision of safe dental care, in the light of the resistance of prions to traditional sterilisation procedures. 5 The findings of the present study suggest that general dental practice is not currently equipped to address some of these issues.…”
Section: Discussionmentioning
confidence: 70%