2019
DOI: 10.1016/j.fm.2019.03.013
|View full text |Cite
|
Sign up to set email alerts
|

Inactivation of Bacillus subtilis spores at various germination and outgrowth stages using intense pulsed light

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 28 publications
0
9
0
Order By: Relevance
“…The IPL device used in this study was self-designed and the device consists of a power supply, treatment chamber, and xenon lamp (NL4006, XAP series, Heraeus Noblelight, Cambridge, UK), which emits light at wavelengths from 200 to 1100 nm [ 29 ]. Before the IPL treatment, 20 g of dried green tea leaves were immersed in 250 mL of tap water, and then sieved to remove water as much as possible.…”
Section: Methodsmentioning
confidence: 99%
“…The IPL device used in this study was self-designed and the device consists of a power supply, treatment chamber, and xenon lamp (NL4006, XAP series, Heraeus Noblelight, Cambridge, UK), which emits light at wavelengths from 200 to 1100 nm [ 29 ]. Before the IPL treatment, 20 g of dried green tea leaves were immersed in 250 mL of tap water, and then sieved to remove water as much as possible.…”
Section: Methodsmentioning
confidence: 99%
“…This strain is a nonpathogenic spoilage and spore-forming bacteria that has a low usage risk in the laboratory environment. B. subtilis was cultured in 3 mL of Bacto TM Brain Heart Infusion (Difco TM , BD, Sparks, MD, USA) broth at 30 °C for 24 h (Jo et al, 2019). Twenty microliters of the culture medium was inoculated on nutrient agar (Difco TM , BD) with added sporulation salt (100 mg/L CaCl 2 and 40 mg/L MnSO 4 ) at 30 °C.…”
Section: Spore Preparationmentioning
confidence: 99%
“…The self-designed laboratory-scale IPL treatment device consisted of a power supply, a cooling system, and a treatment chamber containing a xenon lamp which emits IPL with the 200-1100 nm range of wavelength, fans for ventilation, and a shelf whose distance from the lamp could be adjusted (Jo et al, 2019). The power supply was adjustable for processing time, pulse width (a measure of the time between the beginning and end of the pulse, typically based on the full width half maximum of the pulse shape), frequency, and charging voltage.…”
Section: Ipl Devicementioning
confidence: 99%
See 1 more Smart Citation
“…In another study, intense pulsed light treatment at a total fluence of 7.40 J/cm 2 resulted in a 7 log reduction, indicating the potential of intense pulsed light to inactivate bacterial spores effectively. The best results showed that the inactivation efficiency increases after one h pre-incubation because the numbers of vegetative cells increased with the incubation time [15].…”
Section: Pulsed Lightmentioning
confidence: 99%