Human Body Composition 1993
DOI: 10.1007/978-1-4899-1268-8_61
|View full text |Cite
|
Sign up to set email alerts
|

In Vivo X-Ray Fluorescence Analysis with Applications to Platinum, Gold and Mercury in Man — Experiments, Improvements, and Patient Measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

1995
1995
2022
2022

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 8 publications
0
8
0
Order By: Relevance
“…The improvement can also be made in XFCT by using a cone beam geometry. 23 Future work includes optimizing the imaging geometry using a polarized x-ray source (to reduce the interference of scatter photons 17,19,24 ), and a pixelated CZT photon-counting detector panel (to shorten imaging time) with square-hole pixelated collimator. The spectrum and data analysis algorithms will also be improved.…”
Section: Resultsmentioning
confidence: 99%
“…The improvement can also be made in XFCT by using a cone beam geometry. 23 Future work includes optimizing the imaging geometry using a polarized x-ray source (to reduce the interference of scatter photons 17,19,24 ), and a pixelated CZT photon-counting detector panel (to shorten imaging time) with square-hole pixelated collimator. The spectrum and data analysis algorithms will also be improved.…”
Section: Resultsmentioning
confidence: 99%
“…It is known that several drugs contain heavy elements in their chemical composition [121,122] [126]. Sr-based drugs increase bone mass in postmenopausal osteoporosis patients and reduce fracture risk [127][128][129][130][131].…”
Section: Highlighting Heavy Elements In Drugsmentioning
confidence: 99%
“…These include portable radiography apparatus [96], which can define an area of interest for extraction of biological samples if possible and necessary for subsequent characterization. XRF (for elemental analysis and quantification) [97,98], FTIR [99][100][101][102] or Raman [103][104][105] spectroscopies (to determine the nature and amount of chemical compounds present in the sample) constitute at least three characterization techniques which can be applied in vivo. It is worth mentioning that biological fluids (or actual tissue in the case of accident trauma) can also be analysed, in which case, two other techniques namely X-ray Diffraction (XRD, to determine the nature and quantity of any crystalline phases present in the sample) and tabletop SEM (for submicrometer scale surface imaging) can also be applied.…”
Section: In Vivo Analysis At the Physician's Surgery Or Place Of Injurymentioning
confidence: 99%