2020
DOI: 10.1016/j.dental.2020.05.015
|View full text |Cite
|
Sign up to set email alerts
|

In vivo temperature rise and acute inflammatory response in anesthetized human pulp tissue of premolars having Class V preparations after exposure to Polywave® LED light curing units

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0
4

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 36 publications
0
10
0
4
Order By: Relevance
“…One study stated it was followed the LCU manufacturer’s protocol without specifying the procedure [ 27 ]. Thirteen studies reported in detail the irradiation technique applied [ 10 , 11 , 14 , 16 , 17 , 21 , 22 , 28 , 29 , 30 , 31 , 32 , 33 ].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…One study stated it was followed the LCU manufacturer’s protocol without specifying the procedure [ 27 ]. Thirteen studies reported in detail the irradiation technique applied [ 10 , 11 , 14 , 16 , 17 , 21 , 22 , 28 , 29 , 30 , 31 , 32 , 33 ].…”
Section: Resultsmentioning
confidence: 99%
“…® 3 (Coltene, OH, USA) VALO ® (Ultradent, UT, USA) Demi Ultra ™ (Kerr, Orange, CA, USA) 1200 1600 1000 or 1400 4 1215 or 1100–1330 4 20 15 20 or 4 4 20 or 20 4 The LCUs were placed in a support with the light guide touching the buccal surface of the teeth and four light emissions were made with 30 s intervals. Gross et al, 2020 [ 29 ] In Vivo First premolars requiring extraction exposed to a Polywave LED LCU Experimental LCU (Ivoclar Vivadent, Schaan, Liechtenstein) 10,000 1,2 10,000 Bluephase ® 20i (Ivoclar Vivadent, Liechtenstein) 1200 10, 20, 60 LCU tip was placed against the buccal tooth surface, directly centered over the Class V preparation. Sadeghyar, Watts and Schedle, 2020 [ 30 ] In Vitro Ultra-fast polimerization of bulk-fill resin-based composite RAFT-modified Bluephase ® Power Cure (Ivoclar Vivadent, Schaan, Liechtenstein) 3000 3 3770.3 (±35.30) Bluephase ® Power Cure (Ivoclar Vivadent, Schaan, Liechtenstein) 1200 10 The LCU was placed perpendicular, directly on the top surface of the cylinder.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Die ausgestrahlten Photonen eines Lichtgerätes können aber auch die Pulpa beeinflussen. In einer kürzlich erschienenen Studie [74] wurde der intrapulpale Temperaturanstieg während des Belichtens einer tiefen Zahnhalskavität gemessen an aus kieferorthopädischen Gründen zu extrahierenden Prämolaren und anschließend die Pulpa histologisch untersucht. Zur Anwendung kamen ein kommerzielles Lichtgerät (Bluephase 20i, Fa.…”
Section: Temperaturentwicklung Während Der Lichthärtungunclassified