2000
DOI: 10.1006/bbrc.2000.2518
|View full text |Cite
|
Sign up to set email alerts
|

In Vivo Metabolic Imaging of Cardiac Bioenergetics in Transgenic Mice

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
25
1

Year Published

2001
2001
2015
2015

Publication Types

Select...
6
3

Relationship

2
7

Authors

Journals

citations
Cited by 33 publications
(31 citation statements)
references
References 22 publications
5
25
1
Order By: Relevance
“…The values of metabolite contents determined by NMR spectroscopy of the perfused hearts showed a significant 10% decrease in PCr-to-ATP ratio in CH hearts ( Table 2, P Ͻ 0.01). These results may be related to the classical energetic failure observed in hypoxia (19,32,40). MoCA analysis.…”
Section: Resultsmentioning
confidence: 67%
“…The values of metabolite contents determined by NMR spectroscopy of the perfused hearts showed a significant 10% decrease in PCr-to-ATP ratio in CH hearts ( Table 2, P Ͻ 0.01). These results may be related to the classical energetic failure observed in hypoxia (19,32,40). MoCA analysis.…”
Section: Resultsmentioning
confidence: 67%
“…The effects of general overexpression of GH are known from the studies performed on transgenic mice with overexpression of bovine GH in the whole body [10,[26][27][28][29]. These animals are characterised by increased total BW as well as increased weight of other internal organs including the heart.…”
Section: Discussionmentioning
confidence: 99%
“…The MR imaging and spectroscopy experiments were performed on a 2.35 Tesla (T) horizontal magnet with a 20-cm bore (Bruker Biospec 24/30) interfaced with an X-32 acquisition system giving operating frequencies for 1 H and 31 P MR 100 and 40.5 MHz, respectively. The experiments were performed according to the procedure as previously described [10]. The size of the volume of interest (VOI) for cardiac spectroscopy was 8 · 4 · 4 mm 3 (128 lL, Figs.…”
Section: In Vivo Volume-selective 31 P Mrs Of Heart and Brainmentioning
confidence: 99%
“…Left thoracotomy was performed and 500 000 hES diluted in 50 μL hES were injected with a 31 gauge needle directly into the anterior part of the LV wall at a single injections site. The MR imaging experiments were performed on a 2.35 Tesla (T) horizontal magnet with a 20 cm bore Bruker Biospec 24/30 magnet according to the procedure previously described (Omerovic et al, 2000(Omerovic et al, , 1999. In vivo MRI of the heart was performed 24 h and 5 days after the transplantation of the hES under 1% isoflurane anesthesia.…”
Section: In Vivo Mrimentioning
confidence: 99%