2012
DOI: 10.1016/j.jbiomech.2012.05.043
|View full text |Cite
|
Sign up to set email alerts
|

In vivo kinematics and articular surface congruency of total ankle arthroplasty during gait

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 39 publications
0
7
0
Order By: Relevance
“…A concurrent inversion moment has been observed during gait in healthy individuals as well as those using an ankle-foot orthosis [6770]. Although a goal of this on-going research is to restore plantarflexion or dorsiflexion with absent or balanced inversion and eversion, physiological data suggest that it may not be necessary.…”
Section: Discussionmentioning
confidence: 99%
“…A concurrent inversion moment has been observed during gait in healthy individuals as well as those using an ankle-foot orthosis [6770]. Although a goal of this on-going research is to restore plantarflexion or dorsiflexion with absent or balanced inversion and eversion, physiological data suggest that it may not be necessary.…”
Section: Discussionmentioning
confidence: 99%
“…Gait analysis shows that no characteristic gait pattern for secondary motions of TAR patients exists [82][83][84][85][86]. Therefore, defining a characteristic gait pattern for wear testing is challenging.…”
Section: Wear Testmentioning
confidence: 99%
“…They found that the range of sagittal rotation was maintained during the stance phase of gait after this TAA implantation; however, the axial and coronal rotations were less than those of the natural ankle 23 . Incongruency of the articular surface occurred in 40% of the patients 23 .…”
Section: Licensee Oa Publishing London 2013 Creative Commons Attribumentioning
confidence: 94%
“…In the main fixation, a screw was generally used to link the tibial component and bone rather than cement ( Figure 4) 22 . Yamaguchi et al 23 measured in vivo kinematics of these prostheses (two-component TAA) and assessed the congruency of the articular surface during the stance phase of gait. They found that the range of sagittal rotation was maintained during the stance phase of gait after this TAA implantation; however, the axial and coronal rotations were less than those of the natural ankle 23 .…”
Section: Licensee Oa Publishing London 2013 Creative Commons Attribumentioning
confidence: 99%
See 1 more Smart Citation