2017
DOI: 10.1016/j.jbiomech.2017.09.019
|View full text |Cite
|
Sign up to set email alerts
|

In vivo fascicle length measurements via B-mode ultrasound imaging with single vs dual transducer arrangements

Abstract: Ultrasonography is a useful technique to study muscle contractions in vivo, however larger muscles like vastus lateralis may be difficult to visualise with smaller, commonly used transducers. Fascicle length is often estimated using linear trigonometry to extrapolate fascicle length to regions where the fascicle is not visible. However, this approach has not been compared to measurements made with a larger field of view for dynamic muscle contractions. Here we compared two different single-transducer extrapola… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
34
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 42 publications
(36 citation statements)
references
References 22 publications
0
34
0
Order By: Relevance
“…The error for estimating fascicle with the extrapolation method has been reported to be 2%‐7% and could potentially be larger when considering the high speed of drop and ground contact intensity (>3 m/s at 75 cm). A recent study suggests that using two synchronized in‐series transducers could overcome this limit and avoid absolute fascicle lengths misestimation compared to extrapolated method . As previously reported with the single transducer method, the fascicle data set may not perfectly reflect fascicle behavior; however, it could be assumed that this method does not alter the effects of landing height and type (ie, “similar differences in muscle contraction dynamics within participants.”).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The error for estimating fascicle with the extrapolation method has been reported to be 2%‐7% and could potentially be larger when considering the high speed of drop and ground contact intensity (>3 m/s at 75 cm). A recent study suggests that using two synchronized in‐series transducers could overcome this limit and avoid absolute fascicle lengths misestimation compared to extrapolated method . As previously reported with the single transducer method, the fascicle data set may not perfectly reflect fascicle behavior; however, it could be assumed that this method does not alter the effects of landing height and type (ie, “similar differences in muscle contraction dynamics within participants.”).…”
Section: Discussionmentioning
confidence: 99%
“…A recent study suggests that using two synchronized in‐series transducers could overcome this limit and avoid absolute fascicle lengths misestimation compared to extrapolated method . As previously reported with the single transducer method, the fascicle data set may not perfectly reflect fascicle behavior; however, it could be assumed that this method does not alter the effects of landing height and type (ie, “similar differences in muscle contraction dynamics within participants.”). In our study, we estimate tendinous tissues length changes from fascicle length estimation and lower limb joint angles.…”
Section: Discussionmentioning
confidence: 99%
“…technique cannot be implemented), the use of dual probe array (17) or multiple scan sites should be further investigated on BFlh.…”
Section: A C C E P T E Dmentioning
confidence: 99%
“…A movement initiation threshold was set at 90% of the maximum isometric torque recorded at the 100 0 knee angle. and sample rate of 80 Hz, TELEMED, Vilnius, Lithuania) that were held end-to-end in a custom frame and secured to the lateral thigh (14). Markings were made on the skin with a semipermanent marker so the position of the transducers could be replicated for the cycling protocol.…”
Section: Muscle Force-length-velocity Relationshipmentioning
confidence: 99%