2006 IEEE Nuclear Science Symposium Conference Record 2006
DOI: 10.1109/nssmic.2006.353824
|View full text |Cite
|
Sign up to set email alerts
|

In Vivo Dual-Isotope SPECT Imaging with Improved Energy Resolution

Abstract: Cadmium Zinc Telluride, or CZT, cameras offer dual-isotope imaging capabilities impossible to duplicate using any other preclinical molecular imaging system. This new technology will enable the investigation of multiple biological processes in parallel and open new areas in research and drug development. The dual-isotope capability is due to the improved energy resolution of CZT (4.5% for 99m Tc), which is 2-3 times better than in existing systems. This improved energy resolution allows for the rejection of mo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
18
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 24 publications
(18 citation statements)
references
References 3 publications
(1 reference statement)
0
18
0
Order By: Relevance
“…C OMPOUND semiconductors such as CdZnTe that operate at room temperature with high sensitivity and high stopping power are being utilized in many applications including industrial gauging, nuclear safeguards, transportation security, medical and industrial imaging, along with a range of scientific applications including astrophysics [1]- [4]. Recently there is a growing interest to use the detectors for high flux multi-energy binning imaging [5].…”
Section: Introductionmentioning
confidence: 99%
“…C OMPOUND semiconductors such as CdZnTe that operate at room temperature with high sensitivity and high stopping power are being utilized in many applications including industrial gauging, nuclear safeguards, transportation security, medical and industrial imaging, along with a range of scientific applications including astrophysics [1]- [4]. Recently there is a growing interest to use the detectors for high flux multi-energy binning imaging [5].…”
Section: Introductionmentioning
confidence: 99%
“…All images were acquired on a General Electric Triumph Trimodality (SPECT/PET/CT) pre-clinical scanner. This scanner uses CZT based SPECT technology [1] and the APD based PET technology with LYSO and LGSO crystals [2]. The mating of these systems in one scanner allows the investigation of the acquisition of PET and SPECT images with both modality radiotracers in the field of view (FOV) while eliminating any inherent image registration issues.…”
Section: Methodsmentioning
confidence: 99%
“…The remaining deviations are mainly due to fluorescence escapes between adjacent pixels. Despite the fact that the pixel aperture has been more than halved, charge sharing plays only a minor role compared to the effects of optical cross-talk 3 . The Detector Response Functions of the indirect and direct conversion detector set-ups are shown in Figs.…”
Section: ) Electronic Read-outmentioning
confidence: 99%
“…SPECT prototypes in cardiology, scintimammography and small animal imaging have been presented, [1]- [3]. The authors report improved spectral resolution and underline the potential to perform dual-isotope imaging.…”
mentioning
confidence: 99%