2017
DOI: 10.2174/1573411012666160211235640
|View full text |Cite
|
Sign up to set email alerts
|

In vivo Distribution of Tiotropium in a Rodent Model Utilizing AP-SMALDI Mass Spectrometry Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…Recently, important progress has been achieved in tissue preparation combined with novel MSI instrumentation to generate high-quality data. In addition, MSI can now aid in interrogating the spatial distribution of native drug compounds and drug metabolites within tissues at the resolution of a single cell (Sugihara et al 2018;Torok et al 2015Torok et al , 2017Végvári et al 2017). Cold compounds are being measured by MSI, i.e.…”
Section: Drug Imaging By Mass Spectrometrymentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, important progress has been achieved in tissue preparation combined with novel MSI instrumentation to generate high-quality data. In addition, MSI can now aid in interrogating the spatial distribution of native drug compounds and drug metabolites within tissues at the resolution of a single cell (Sugihara et al 2018;Torok et al 2015Torok et al , 2017Végvári et al 2017). Cold compounds are being measured by MSI, i.e.…”
Section: Drug Imaging By Mass Spectrometrymentioning
confidence: 99%
“…MALDI-MSI is more and more widely used to describing drug distributions in experimental systems. Nevertheless, more than 100 reports have been published where the technology has been used to characterise drug compounds in experimental drug predicting models (Connell et al 2015;Kwon et al 2015;Marko-Varga et al 2012a;Végvári et al 2017). Until recently, only our own studies have described such drug distribution in humans.…”
Section: Drug Imaging By Mass Spectrometrymentioning
confidence: 99%
“…In drug distribution detection, an in vivo experiment in a rodent model utilizing AP MALDI MSI was conducted by Akos Vegvari's team in 2017, revealing the distribution of tiotropium with 10 μm resolution. 105 Meanwhile, AP MALDI imaging mass microscope combined with a relative exposure approach was employed by Tai Rao et al to study pharmacokinetics via octreotide analysis in mouse target tissues. 106 In 2020, three kinds of MSI, desorption electrospray ionization (DESI) MSI, MALDI MSI, and AP MALDI MSI, were employed by Ariful Islam's team for rap mapping of imipramine, chloroquine, and their metabolites in mice kidneys and brains.…”
Section: Applications Using Ap Maldimentioning
confidence: 99%
“…Scanning microprobe matrixassisted laser desorption ionization (SMALDI) mass was invented by Hubert, M. in 2002 (Spengler andHubert, 2002). It was further improved as atmospheric pressure scanning microprobe matrix-assisted laser desorption/ionization mass spectrometry (AP-SMALDI MS) for imaging (Vegvari et al, 2017;Bhandari et al, 2018;Bredehoeft et al, 2019;Kadesch et al, 2020;Mokosch et al, 2021;Mueller et al, 2021;Righetti et al, 2021), while atmospheric pressure MALDI ion sources AP-MALDI have also been developed for MSI (Guenther et al, 2011;Jackson et al, 2018;Keller et al, 2018) and achieved a lateral resolution at 1.4 μm (Kompauer et al, 2017).…”
Section: Classical Ion Sourcesmentioning
confidence: 99%
“…Furthermore, MALDI ion resources can be easily coupled with high-resolution (resolving power) mass analyzers, such as TOF, FT-ICR, and Orbitrap, which provide high mass accuracy for MSI targets. During the recent years, with the developments of some new MALDI ion sources, such as atmosphere pressure AP-MALDI (Kompauer et al, 2017), AP-SMALDI (Vegvari et al, 2017;Bhandari et al, 2018;Bredehoeft et al, 2019;Kadesch et al, 2020;Mokosch et al, 2021;Mueller et al, 2021;Righetti et al, 2021), MALDI-2 (Soltwisch et al, 2015), transmission MALDI-2 (Niehaus et al, 2019), and nano laser probed-based laser desorption ionization (Meng et al, 2020), the lateral resolution of MALDI-MSI will possibly achieve nm or µm level for single cell and even subcellular scale imaging. Finally, the scanning speed of MALDI-MSI largely depends on the speed of MS detection, spectra recording and data processing.…”
Section: General Marks and Conclusionmentioning
confidence: 99%